Status
Conditions
Treatments
About
The investigators propose a new wash-in technique for sevoflurane low flow anesthesia with fresh gas flow of O2:N2O or O2:air 1:1 L/min with sevoflurane 8%.
The objective of this study is to identify time to achieve alveolar concentration of sevoflurane at 1, 1.5, 2, 2.5, 3, and 3.5%
Full description
The benefits of low flow anesthesia are economic, less pollution, more heat and humidity preservation but it requires appropriate wash-in phase. The current wash-in protocols for sevoflurane are complicated and time consuming. The investigators propose a new 1-1-8 sevoflurane wash-in protocol which is more simple and predictable.
The objective of this study is to identify time to achieve alveolar concentration of sevoflurane at 1, 1.5, 2, 2.5, 3, and 3.5% with 1-1-8 wash-in protocol.
All patients will receive iv propofol 2 mg/kg as induction agent and succinyl choline 1.5 mg/kg for intubation. Then the ventilation will be controlled to achieve end-tidal CO2 30-35 mmHg with O2:N2O or O2:air 1:1 L/min with sevoflurane 8%. Time to achieve alveolar concentration of sevoflurane at 1, 1.5, 2, 2.5, 3, and 3.5% will be recorded and analyzed. After that, the concentration of sevoflurane and anesthetic technique will be adjusted to requirement of anesthesiologist.
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Exclusion criteria
Primary purpose
Allocation
Interventional model
Masking
100 participants in 1 patient group
Loading...