3D Custom Plate vs. Standard Titanium Plates for Mandibular Sub-condylar Fractures Fixation

E

Esraa Mosad Tawfik

Status

Not yet enrolling

Conditions

Mandibular Sub-condylar Fracture

Treatments

Device: Standard titanium fixation plates
Device: 3D custom plate

Study type

Interventional

Funder types

Other

Identifiers

NCT06978530
3D-SCF-RCT-2025

Details and patient eligibility

About

This randomized clinical trial aims to conduct a comprehensive clinical and radiographic evaluation by comparing the efficacy of standard titanium fixation plates with three dimensional custom plate in the management of sub-condylar fractures. By assessing the clinical outcomes, accuracy of reduction of the fracture segments, and bite force promoted by both fixation modalities.

Enrollment

30 estimated patients

Sex

All

Ages

18 to 60 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Displaced sub condylar fractures, requiring open reduction and rigid internal fixation
  • Age ranges from 18 to 60 years
  • Fracture duration less than 2 weeks
  • Patients with adequate follow up duration for outcome assessment

Exclusion criteria

  • Comminuted sub condylar fractures
  • Patients with severe systemic diseases that may affect fracture healing
  • Presence of any pathology at the fracture site
  • Patients with previous history of mandibular surgery
  • Medically compromised patients who are not fit to undergo surgery under general anesthesia
  • Patients with in complete medical records or missing follow up data

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Single Blind

30 participants in 2 patient groups

3D Custom Plate group
Experimental group
Description:
Patients in this group will undergo open reduction and internal fixation of displaced mandibular sub-condylar fractures using preoperatively designed and 3D-printed patient-specific titanium plates.
Treatment:
Device: 3D custom plate
Standard titanium plates group
Active Comparator group
Description:
Patients in this group will undergo open reduction and internal fixation of displaced mandibular sub-condylar fractures using the conventional technique, involving either two standard titanium miniplates or a single 2.3 mm titanium plate.
Treatment:
Device: Standard titanium fixation plates