ClinicalTrials.Veeva

Menu

3D Printed Mask for GBM and Brain Mets

University Health Network, Toronto logo

University Health Network, Toronto

Status

Completed

Conditions

Brain Cancer

Treatments

Device: 3D-printed mask
Device: Thermoplastic mask

Study type

Interventional

Funder types

Other

Identifiers

NCT04114786
18-5753

Details and patient eligibility

About

This is a single site, investigator initiated study that aims to explore the feasibility of using a personalized 3D printed immobilization mask for CNS patients undergoing radiation therapy.

For the purpose of this study, patients will undergo the standard CT SIM, and MR SIM necessary for radiation therapy, creating the masks from the MRIs. Prior to the start of their treatment, patients will have an additional CT scan with the 3D printed mask to confirm safety and treatment accuracy. Patients will then proceed with their standard radiation therapy, immobilized with the mask. There will be a control group that will be treated with the standard thermoplastic mask, as a comparison measure. Both groups will complete a mask tolerability questionnaire throughout the course of their treatment to capture the level of discomfort patients may feel with either masks.

Full description

All patients referred for radiotherapy have had a previous diagnostic imaging study (CT-scan or more commonly MRI) showing the disease at the central nervous system (CNS). Moreover, after surgical biopsy or resection, many Centers perform repeated post-operative imaging. Despite all prior imaging, when radiotherapy treatment is decided, all patients undergo another imaging study (CT simulation [CT-sim]) in which patient's head is placed in a reproducible position, and endure a moulding procedure to create a personalized plastic mask for securing the patient's head in a fixed position during the CT acquisition, and reproduced at the subsequent radiation treatment sessions. Typical wait times between moulding, CT-sim and the first radiation treatment is 3-7 days. If a method would be available to accurately recreate the patient's position during diagnostic imaging and reproduce it during radiation treatments without the need for a moulding session or CT-sim, the treatment process can be streamlined and wait times shortened for patients.

Previous studies using 3D printing technology in radiotherapy (such as brachytherapy applicators) have shown that these employed materials are safe for use in clinical settings, and 3D printers can accurately produce devices of various shapes and sizes for clinical use.

In this study, we propose a novel workflow in which patient's position at diagnostic imaging is reproduced with a 3D-printed patient-specific immobilization device, enabling the use of the same diagnostic imaging for planning purposes in lieu of dedicated simulation and moulding sessions, to decrease wait times for patients between diagnostic imaging and start of radiation treatment.

Enrollment

40 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Age >18 years
  • Patient with high-grade glioma considered for external beam radiotherapy (15 fractions or more) with or without Temozolamide, or patients with brain metastases considered for fractionated LINAC-based external beam radiotherapy (5 fractions or more) as primary or adjuvant treatment.
  • No contraindications to MRI
  • No other medical conditions deemed by the PI to make patient ineligible for the study (i.e. claustrophobia, confusion, delirium).

Exclusion criteria

  • None

Trial design

Primary purpose

Diagnostic

Allocation

Non-Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

40 participants in 2 patient groups

3D-printed mask
Experimental group
Description:
Patients will undergo the standard CT SIM, and MR SIM necessary for radiation therapy, creating the masks from the MRIs. Prior to the start of their treatment, patients will have an additional CT scan with the 3D printed mask to confirm safety and treatment accuracy. Patients will then proceed with their standard radiation therapy, immobilized with the mask.The group will complete a mask tolerability questionnaire throughout the course of their treatment to capture the level of discomfort patients may feel with either masks.
Treatment:
Device: 3D-printed mask
Control group
Active Comparator group
Description:
Control group that will be treated with the standard thermoplastic mask, as a comparison measure. The group will complete a mask tolerability questionnaire throughout the course of their treatment to capture the level of discomfort patients may feel with either masks.
Treatment:
Device: Thermoplastic mask

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2025 Veeva Systems