ClinicalTrials.Veeva

Menu

577nm Micropulse Laser Versus 532nm Subthreshold Laser Photocoagulation for Diabetic Macular Edema

Sun Yat-sen University logo

Sun Yat-sen University

Status

Completed

Conditions

Diabetic Macular Edema

Treatments

Device: 532-SLP
Device: 577-MPL

Study type

Interventional

Funder types

Other

Identifiers

NCT02406157
ZOC-MPLD

Details and patient eligibility

About

This randomized, parallel controlled, clinical-trial aims to evaluate the therapeutic efficacy and safety of 577nm micropulse laser photocoagulation for diabetic macular edema compared with 532 subthreshold laser photocoagulation.

Full description

  1. To evaluate the efficacy of 577nm micropulse laser photocoagulation with grid/focal treatment for diabetic macular edema.
  2. To investigate influence of 577nm micropulse laser photocoagulation on structure and function of macula compared with 532nm subthreshold laser photocoagulation.

Enrollment

124 patients

Sex

All

Ages

19 to 80 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Aged >18 years
  • Patients with diabetes mellitus type 2
  • Diagnosed as diabetic retinopathy with Clinical Significant Macular Edema
  • Central retinal thickness(CRT) of more than 250μm as measured by optical coherence tomography (OCT)
  • ETDRS visual acuity >19 letters (Snellen equivalent of 20/400 or better)
  • No macular laser coagulation or surgery or medicine therapy of macular edema within the last 6 months
  • Blood glucose was controlled steadily(HbA1c≤10%)

Exclusion criteria

  • Taking part in other clinical trial within 3 months
  • Planning panretinal photocoagulation(PRP) within 3 months
  • Performed cataract surgery in the last 3 months
  • Accompanied with other retinal vascular disease that can lead to macular edema, for example branch retinal vein occlusion(BRVO),central retinal vein occlusion(CRVO)
  • Accompanied with severe opacity of refractive media that maybe impact therapy and observation
  • Accompanied with nystagmus
  • Accompanied with some history that maybe interfere with result or increase the risk of patients

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Double Blind

124 participants in 2 patient groups

577-MPL
Experimental group
Description:
577nm micropulse laser photocoagulation(577MPL) treatment to the macular area of retinal thickening with a focal or grid pattern
Treatment:
Device: 577-MPL
532-SLP
Active Comparator group
Description:
532nm subthreshold laser photocoagulation(532-SLP) treatment to the macular area of retinal thickening with a focal or grid pattern
Treatment:
Device: 532-SLP

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems