ClinicalTrials.Veeva

Menu

A Fully-closed Loop, Pramlintide and Insulin, Artificial Pancreas Clinical Trial for Adults With Type 1 Diabetes (FCL)

McGill University logo

McGill University

Status

Completed

Conditions

Type 1 Diabetes

Treatments

Drug: Pramlintide
Device: Artificial Pancreas
Drug: Aspart
Drug: Fiasp

Study type

Interventional

Funder types

Other

Identifiers

NCT05199714
2022-8225

Details and patient eligibility

About

The investigators aim to assess the glycemic outcomes of a fully automated insulin-and-pramlintide artificial pancreas and a comparator insulin-alone artificial pancreas with carbohydrate matched boluses.

Full description

The aim of this pilot study is to generate additional data of (i) a Fiasp-alone artificial pancreas with carbohydrate-matched boluses, compared to (ii) a Fiasp-plus-Pramlintide fully automated artificial pancreas with no meal announcement in an outpatient free-living setting. The study is not powered, nor aims to answer a scientific hypothesis related to the efficacy of the pramlintide and insulin closed-loop systems.

Design

The investigators will undertake a randomized crossover study to compare the following strategies:

  1. Insulin-alone artificial pancreas with carbohydrate-matched boluses

  2. Fiasp and pramlintide artificial pancreas with no meal announcement. Ratio of 1 unit of insulin for 8μg of pramlintide.

  3. Fiasp and pramlintide artificial pancreas with no meal announcement. Ratio of 1 unit of insulin for 10μg of pramlintide.

    Each participant will be offered the opportunity to further participate in two optional additional arms:

  4. Aspart and pramlintide artificial pancreas with no meal announcement. Ratio of 1 unit of insulin for 8μg of pramlintide.

  5. Aspart and pramlintide artificial pancreas with no meal announcement. Ratio of 1 unit of insulin for 10μg of pramlintide.

Aspart is used in this optional arm as it is the slower-acting version of Fiasp and can therefore be used to draw reasonable comparisons. Further, Aspart is an FDA approved insulin which is commonly sold and prescribed in North America. Several co-formulations are being developed with insulin, pramlintide, and glucagon. Given the widespread adoption and use of Aspart, it makes this insulin a good candidate for use in co-formulations and an excellent option for transition to market, where they will impact many individuals living with diabetes.

Treatment period: Each intervention will last 14 hours. At-home run-ins, lasting two to four days, will occur prior to the pramlintide interventions. The interventions containing pramlintide with the same insulin will occur in sequence, one immediately after the other. The first pramlintide-and-Fiasp intervention will use a ratio of 8μg pramlintide/1unit of insulin and will be followed by the second pramlintide-and-Fiasp intervention the next day with a 10μg/1unit ratio. A similar schedule will be applied to the optional Aspart-and-pramlintide interventions. There will be a 2-29-day washout period between the Fiasp-and-pramlintide, Fiasp-alone, and Aspart-and-pramlintide interventions. Participants will be followed up remotely 1-2 days after the end of each intervention to ensure their washout period is going smoothly and will inquire about any adverse events. Remote contact can be performed via phone, email, text message or other reasonable communication channel. Participants will also be followed up remotely 1-2 days and 1-2 weeks after the end of their participation in the study.

Enrollment

12 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Females and males ≥ 18 years of age.
  • Clinical diagnosis of type 1 diabetes for at least 12 months. The diagnosis of type 1 diabetes is based on the investigator's judgment; C peptide level and antibody determinations are not needed.
  • Use of insulin pump therapy for at least 3 months.
  • Effective birth-control use in individuals of childbearing potential. Individuals of child-bearing potential must agree to use a highly effective method of birth control.

Exclusion criteria

  • Current or ≤ 1 month use of other antihyperglycemic agents (SGLT2I (sodium-glucose transporter), GLP-1(glucagon-like peptide), Metformin, etc.).
  • Current use of glucocorticoid medication (except low, stable does and inhaled steroids).
  • Individuals with confirmed gastroparesis.
  • Use of medication that alters gastrointestinal motility.
  • Planned or ongoing pregnancy.
  • Breastfeeding individuals.
  • Severe hypoglycemia requiring hospitalization in the past three months.
  • Severe diabetic ketoacidosis episode in the past three months.
  • Clinically significant nephropathy, neuropathy or retinopathy as judged by the investigator.
  • Recent (< 6 months) acute macrovascular event e.g., acute coronary syndrome or cardiac surgery.
  • Other serious medical illness likely to interfere with study participation or with the ability to complete the trial by the judgment of the investigator.

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Crossover Assignment

Masking

None (Open label)

12 participants in 5 patient groups

Fiasp-and-pramlintide fully automated system (8μg)
Experimental group
Description:
Fiasp and pramlintide artificial pancreas with no meal announcement. Ratio of 1 unit of insulin for 8μg of pramlintide.
Treatment:
Drug: Pramlintide
Device: Artificial Pancreas
Drug: Fiasp
Fiasp-alone with carbohydrate-matched boluses
Active Comparator group
Description:
The Fiasp-alone intervention will have a 14 hour duration. During which, carbohydrate counting will inform insulin bolus doses based on insulin to carbohydrate ratios.
Treatment:
Drug: Fiasp
Aspart-and-pramlintide fully automated system (10μg)
Experimental group
Description:
Aspart and pramlintide artificial pancreas with no meal announcement. Ratio of 1 unit of insulin for 10μg of pramlintide.
Treatment:
Drug: Aspart
Drug: Pramlintide
Device: Artificial Pancreas
Fiasp-and-pramlintide fully automated system (10μg)
Experimental group
Description:
Fiasp and pramlintide artificial pancreas with no meal announcement. Ratio of 1 unit of insulin for 10μg of pramlintide.
Treatment:
Drug: Pramlintide
Device: Artificial Pancreas
Drug: Fiasp
Aspart-and-pramlintide fully automated system (8μg)
Experimental group
Description:
Aspart and pramlintide artificial pancreas with no meal announcement. Ratio of 1 unit of insulin for 8μg of pramlintide.
Treatment:
Drug: Aspart
Drug: Pramlintide
Device: Artificial Pancreas

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems