About

Malignant central airway stenosis caused by primary or metastatic malignant tumor may lead to dyspnea even death of patients.With the rapid development of interventional pulmonology, bronchoscopic therapy has become the main treatment for malignant central airway stenosis. Metal stent implantation in airway can quickly relieve respiratory obstruction and improve quality of life.However, the tumor tissue can continue to grow into metal stent and obstruct airway again. This is the shortcoming of metal bare stents, which often need further treatment to keep airway open, including ablation, laser, cryotherapy, external radiotherapy or systemic anti-tumor drug therapy.Metal stent implantation combined with external radiotherapy can effectively reduce the incidence of airway restenosis.However, complications of external radiotherapy are high, including bone marrow suppression, radioactive pneumonia, radioactive esophagitis, myocardial injury and tracheoesophageal fistula, of which may cause serious consequences and even cause death of the patient.125I radioactive seeds have been one of the mature radioactive interventional therapy, which release X rays, and γ rays. Because of the short radioactive distance, 125I seeds can destruct tumor cells in tumor site and promote apoptosis and necrosis of tumor cells around the obstruction of the airway, meanwhile cause little damage to the surrounding normal tissues. Some studies showed that 125I seed implantation of lung tumor lesions achieved good short-term results.Therefore, the investigators hypothesize that 125I seeds fixed on the metal bare stent can not only improve the patient's breathing difficulties, but also play a role in killing tumor cells. At present, there have been reports of related clinical cases and monocentric control studies of malignant central airway stenosis treated with the implantation of metal stent with 125I seeds, but there is a lack of multicentric clinical studies with large samples.

Full description

It is an open, multicentric randomized controlled clinical trial conducted in China, and plan to recruiting 200 patients who suffer malignant central airway stenosis. To evaluate the efficacy and safety of metal stent with 125I seeds group and metal bare stent group in the treatment of malignant central airway stenosis, follow-up should be done within 1 week, 1 month, and 3 months after the first treatment, followed by every 3 months. The contents include review of bronchoscopy and chest CT, blood routine, immune indicators (IgA, immunoglobulin M(Ig M), IgG), evaluation of general conditions. The patients of the first group need emission-computed tomography(ECT) imaging or positron emission tomography-computed tomography (PET-CT) examination within 1 month. If the patient has severe dyspnea, emergency bronchoscopy should be performed .

Enrollment

200 estimated patients

Sex

All

Ages

18 to 75 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  1. Age range: 18-75 years old, male or female who is not pregnant
  2. Comply with the diagnosis of malignant central airway stenosis, and undergo chest CT or bronchoscopy to confirm that the stenosis degree is above 50% and need to be implanted with airway metal stent; or the patient has obvious dyspnea due to airway stenosis, obstructive pneumonia
  3. Subjects voluntarily joined the study and signed informed consent, with good compliance and follow-up.
  4. Unable or refused surgery
  5. Unable or refused external radiation therapy
  6. Unable or refuse systemic tumor-related drugs therapy within 3 months

Exclusion criteria

  1. The distal end of the stenosis is unpredictable, and the stent treatment may not be satisfactory;
  2. Severe arrhythmia, acute myocardial ischemia, uncontrollable hypertensive crisis;
  3. Severe coagulopathy
  4. Severe organ dysfunction (except respiratory insufficiency)
  5. Allergic to anesthetics
  6. Airway fistula lesions
  7. The narrow lesion involves 2cm inside the glottis
  8. History of extrathoracic radiation therapy in the past 6 months
  9. Severe myelosuppression

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

200 participants in 2 patient groups

A metal bare stent with 125I seeds
Experimental group
Description:
125I seeds fixed on the metal bare stent, then stent implantation
Treatment:
Procedure: stent implantation
A metal bare stent
Other group
Description:
A metal bare stent implantation
Treatment:
Procedure: stent implantation

Trial contacts and locations

1

Loading...

Central trial contact

Chengshui Chen, doctor; Xiaoxiao Lin, doctor

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems