Status
Conditions
Treatments
About
A three-arm, multi-site clinical evaluation of the ARIES Bordetella Assay for the detection and identification of Bordetella pertussis (B. pertussis) and Bordetella parapertussis (B. parapertussis) nucleic acids in prospectively collected, de-identified, left-over clinical specimens; banked, pre-selected clinical specimens; and contrived specimens.
Full description
The ARIES Bordetella Assay is a real-time polymerase chain reaction (PCR) based qualitative in vitro diagnostic test for the direct detection and identification of Bordetella pertussis (B. pertussis) and Bordetella parapertussis (B. parapertussis) nucleic acid in nasopharyngeal swabs (NPS) specimens obtained from individuals suspected of having a respiratory tract infection attributable to B. pertussis or B. parapertussis.
Clinical nasopharyngeal swab specimens collected using nasopharyngeal swab in transport media will be processed according to the routine procedure followed at the clinical collection site and as ordered by the referring physician. The leftover specimen will be blinded and assigned a unique clinical study specimen number. In order to preserve the confidentiality of subjects, the following procedures will be implemented at each site:
Multiple aliquots of each left-over specimen will be generated. One aliquot of each specimen will be shipped to a laboratory where the reference method (two validated real-time PCR methods for each, B. pertussis and B. parapertussis) will be performed. A second aliquot of each specimen will be used by the clinical sites for ARIES Bordetella Assay testing. Additional aliquots of each specimen will be stored frozen (-65 to -95°C) at the clinical sites and sent separately on dry ice to the Sponsor upon Sponsor's request.
The prospective data set will be supplemented with banked, pre-selected clinical specimens and contrived specimens that tested positive by a comparator method for B. pertussis and B. parapertussis. If contrived specimens are required, these specimens will be prepared then blinded, aliquoted, randomized and frozen (-65 to -95°C) until distributed to the clinical testing sites by the Sponsor.
The clinical data will be automatically generated from the ARIES System software. The system will report the specimen as B. pertussis and B. parapertussis positive (Co-infection), B. pertussis positive, B. parapertussis positive, B. pertussis and B. parapertussis negative or Invalid. Invalid results will be retested and both the original data and the retest data will be reported. The clinical data will be compared to the reference data and recorded in the clinical study reports.
Enrollment
Sex
Volunteers
Inclusion criteria
Exclusion criteria
Primary purpose
Allocation
Interventional model
Masking
1,052 participants in 3 patient groups