ClinicalTrials.Veeva

Menu

A Pilot Study to Evaluate an Osteogenic Protein 1 (OP-1) Putty Spinal System and an Autograft Spinal System

O

Olympus

Status

Completed

Conditions

Degenerative Disc Disease

Treatments

Device: TLIF with a PEEK Spacer System and XIA Spinal System

Study type

Interventional

Funder types

Industry

Identifiers

NCT00678171
06-TLF-001

Details and patient eligibility

About

This study will explore the use of recombinant OP-1 in conjunction with surgical treatment of single-level TLIF of the lumbar spine.

Full description

This pilot study is a randomized, multi-center, prospective, controlled study of the efficacy and safety of OP-1 Putty Spinal System in patients requiring a single level transforaminal interbody fusion of the lumbar spine (TLIF).

Enrollment

30 patients

Sex

All

Ages

18 to 80 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  1. The patient is willing and able to understand, sign and date the study-specific, Institutional Review Board (IRB)/Independent Ethics Committee (IEC) approved patient informed consent and applicable privacy regulations.
  2. The patient has a documented diagnosis of DDD with up to Grade I spondylolisthesis demonstrated by radiographic imaging (by plain film/discography within 12 weeks of surgery and/or computed tomography (CT scan/magnetic resonance imaging [MRI].
  3. The patient requires single level lumbar fusion (L2 to S1)

Exclusion criteria

  1. The patient has a history of previous surgery in the lumbar spine with or without attempted fusion {Note: a history of lumbar decompression surgery is permitted}.
  2. The patient has Grade II, Grade III or Grade IV spondylolisthesis.
  3. The patient has gross spinal instability measured on flexion/extension radiographs of >25% translation of the vertebrae, or ≥20 degrees of angular motion or has significant (>10%) scoliosis.
  4. The patient is receiving treatment (before, during or after surgery) with a drug that interferes with bone metabolism or is being treated with a bone growth stimulator.
  5. The patient has been treated in the last 6 months with radiation, chemotherapy, immunosuppression or systemic corticosteroids.
  6. The patient has a history of, or has any malignancy or spinal tumor of any type, with the exception of a history of a treated basal or squamous cell carcinoma.
  7. The patient is morbidly obese (defined as body mass index [BMI] > 35).
  8. The patient currently uses tobacco products, within 3 weeks prior to time of treatment.
  9. The patient is known to require at the time of treatment, additional surgery to the lumbar spinal region within the next 6 months or has symptomatic multilevel degenerative disease requiring possible instrumented fusion of more than one level.
  10. The patient has previously been treated with or exposed to any Bone Morphogenetic Proteins (BMPs).
  11. The patient is contraindicated for iliac crest autografting in that the Investigator believes the patient would be unable to provide sufficient quantity or adequate quality autograft (e.g., osteoporosis as defined by this protocol) from a unilateral iliac crest harvest.
  12. The patient has a previous diagnosis of Paget's disease, osteomalacia or any other endocrine or metabolic bone disease that affects osteogenesis.
  13. The patient has a documented history of osteoporosis or has a risk of osteoporosis as defined by an Osteoporosis Risk Assessment Instrument (ORAI) score of ≥ 9 and a DEXA Scan T score of ≥-2.5 standard deviations below the normal range within one year of enrollment.

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Factorial Assignment

Masking

None (Open label)

30 participants in 2 patient groups

OP-1 Putty
Experimental group
Description:
Patients randomized to the OP-1 Putty Spinal System arm will receive OP-1 Putty with AVS™TL PEEK Spacer System and XIA® Spinal System.
Treatment:
Device: TLIF with a PEEK Spacer System and XIA Spinal System
Autograft
Active Comparator group
Description:
Patients randomized to the Autograft Spinal System arm will receive iliac crest autograft with AVS™TL PEEK Spacer System and XIA® Spinal System.
Treatment:
Device: TLIF with a PEEK Spacer System and XIA Spinal System

Trial contacts and locations

10

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems