ClinicalTrials.Veeva

Menu

A Prospective Randomized Comparison of the Adenoma Detection Rate With a Disposable Cap (ENDOCUFF VISION®) (Endocuff)

U

Universitätsklinikum Hamburg-Eppendorf

Status

Completed

Conditions

Adenoma Detection Rate

Treatments

Procedure: Endocuff group

Study type

Observational

Funder types

Other
Industry

Identifiers

NCT03442738
PV 5294

Details and patient eligibility

About

The aim of this study is to evaluate the effect of ENDOCUFF VISION® (caps with soft, about 1 cm long lateral feet of rubber ("Endocuff") to flatten the colon folds) on ADR in a real-life setting (general practices) and in a homogenous patient collective (screening colonoscopies only).

It is a prospective randomized multi centric study, with participation of at least 10 study sites (private practice). The study is an inverstigator-initiated trial (IIT).

Depending on the randomization (closed envelope), the patients are examined with the standard instruments without or with ENDOCUFF VISION®.

Group 1: screening colonoscopy with standard colonoscopes with ENDOCUFF VISION® Group 2: screening colonoscopy with standard colonoscopes without cap

Full description

Colonoscopy is currently the best method for the detection of colon carcinomas and, as precursor, adenomas, since these can also be biopsied and removed. Therefore, the screening colonoscopy was introduced at the end of 2002 (covered by state insurance) from the age of 55. The main quality parameter for outcome quality is the adenoma detection rate (ADR), which correlates with the rate of the carcinomas prevented. However, since even smaller polyps, especially if they are flat or sunken, may be relevant for colon cancer development, the aim of colonoscopy should be to be able to recognize and remove as many adenomas as possible. There is a need to optimize the efficiency of screening colonoscopy by increasing the rate of adenoma detection, as it is known from many studies that approximately 15-30% of adenomas can be missed- even though the adenoma rate in the German screening colonoscopy register continues to increase over the years and currently stands at 28%.

Previous studies on the increase of the adenoma detection rate by endoscopy concerning newer endoscope technologies including conventional caps have been almost entirely negative.

For about 2 years, a newer version of ENDOCUFF VISION® caps (caps with soft, about 1 cm long lateral feet of rubber (Endocuff) to flatten the colon folds) is available which has already been used in about 8,000 colonoscopies in Germany and another 10,000 colonoscopies in Europe; there are no studies on this version of Endocuff caps.

The aim of this study is to evaluate the effect of ENDOCUFF VISION® in a real-life setting (general practices) and in a homogenous patient collective (screening colonoscopies only).

It is a prospective randomized multi centric study, with participation of at least 10 study sites (private practice). The study is an inverstigator-initiated trial (IIT).

A new technique for ADR improvement within colonoscopy can only be tested in a comparative study in two groups comparing the adenoma rate between the two groups. An independent gold standard does not exist in this sense, but the confirmation by the endoscopically taken histology serves as gold standard for the diagnosis adenoma. The alternative of double examinations (tandem colonoscopy) in each patient is in the setting of private practice not feasible.

Depending on the randomization (closed envelope), the patients are examined with the standard instruments without or with ENDOCUFF VISION®.

Group 1: screening colonoscopy with standard colonoscopes with ENDOCUFF VISION® Group 2: screening colonoscopy with standard colonoscopes without cap

Enrollment

1,382 patients

Sex

All

Ages

55+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • > 55 years
  • who voluntarily undergo a screening colonoscopy
  • information and signed declaration of consent

Exclusion criteria

  • symptoms that may indicate a colonic disease
  • rectal/colonic bleeding
  • known colon disease for further diagnosis, e.g. Carcinoma, polyps for erosion, inflammatory bowel disease, stenosis
  • follow-up/surveillance after colon carcinoma surgery or polypectomy
  • anticoagulant drugs that make a biopsy or polypectomy impossible
  • poor general condition (from ASA (American Society of Anesthesiologists Classification) III)
  • partial/incomplete colonoscopy planned

Trial design

1,382 participants in 2 patient groups

Group I Endocuff group
Description:
Group I Endocuff cap use
Treatment:
Procedure: Endocuff group
Group II standard colonoscope
Description:
Group II standard colonoscope, no further device used
Treatment:
Procedure: Endocuff group

Trial contacts and locations

9

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems