A Study of Pressure and Flow Characteristics During Inspiration and Expiration Using BreatheMAX® in Healthy Subjects (PFBM)

K

Khon Kaen University

Status

Completed

Conditions

Healthy Subjects

Treatments

Device: BreatheMAX breathing device

Study type

Interventional

Funder types

Other

Identifiers

NCT02847416
KKU2016

Details and patient eligibility

About

the aim of this study are to explore the characteristics of mean airway pressure, oscillatory amplitude and power spectral density (PSD) of oscillatory airway pressure that generate by various loaded and flow rate during expiration and inspiration in healthy subjects and to explore the best loaded and flow rate for airway secretion clearance using the BreatheMAX® device

Full description

For inspiratory group, the resistive load 3, 4, 5, 6 and 7 cm H2O were test with three flow rate: 0.2, 0.4, and 0.6 L/sec in each load. In each flow rate, the subjects were instructed to inspire as deeply as possible with steady flow rate for 3 seconds with end-inspiratory pause for 2-3 seconds through the inspiratory circuit and follow by passive exhalation. For expiratory group, the resistive load and flow rate were test similar inspiratory group. In each flow rate, the subjects were instructed to inspire as deeply as possible through the nose with end-inspiratory pause for 2-3 seconds and partially forced exhalation with reach to 1/3 of expiratory reserve volume (ERV) for at least 3 seconds through expiratory circuit

Enrollment

10 patients

Sex

All

Ages

18 to 35 years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  • the healthy subjects
  • able to breathe against resistive load with the BreatheMAX device
  • good conscious and cooperation

Exclusion criteria

  • fever

Trial design

Primary purpose

Other

Allocation

Randomized

Interventional model

Crossover Assignment

Masking

Single Blind

10 participants in 2 patient groups

Inspiratory group
Experimental group
Description:
the subjects will be instructed to inspire as deeply as possible with steady flow rate for 3 seconds with end-inspiratory pause for 2-3 seconds through the inspiratory circuit and follow by passive exhalation
Treatment:
Device: BreatheMAX breathing device
expiratory group
Experimental group
Description:
the subjects will be instructed to inspire as deeply as possible through the nose with end-inspiratory pause for 2-3 seconds and partially forced exhalation with reach to 1/3 of expiratory reserve volume (ERV) for at least 3 seconds through expiratory circuit
Treatment:
Device: BreatheMAX breathing device