ClinicalTrials.Veeva

Menu

A Study of the TAXUS Liberté Stent for the Treatment of de Novo Coronary Artery Lesions in Small Vessels

Boston Scientific logo

Boston Scientific

Status and phase

Completed
Phase 3

Conditions

Coronary Artery Disease

Treatments

Device: Express2
Device: TAXUS™ Express2
Device: TAXUS Liberté-SR

Study type

Interventional

Funder types

Industry

Identifiers

NCT00371748
TAXUS ATLAS Small Vessel
S2033

Details and patient eligibility

About

TAXUS ATLAS Small Vessel is a global, multi-center, single-arm, trial of patients with coronary arteries less than 2.5 mm in diameter who are treated with the TAXUS Liberté stent versus an historical TAXUS Express control derived from a subset of lesion-matched TAXUS V patients treated with a 2.25 mm stent. The objective of the study is to evaluate clinical and angiographic outcomes of TAXUS Liberté-SR 2.25 mm stent in de novo lesions. The hypothesis is that the TAXUS Liberté-SR stent has non-inferior safety and efficacy to the TAXUS Express-SR stent in the treatment of de novo lesions in small coronary vessels.

Full description

TAXUS ATLAS Small Vessel is a global, multi-center, single-arm, trial of patients receiving the TAXUS Liberté-SR 2.25 mm paclitaxel-eluting stent. The results will be compared with two different historical control groups. The first control group consists of a subset of lesion-matched TAXUS V patients treated with a 2.25 mm TAXUS Express-SR paclitaxel-eluting stent. The objective of this analysis is to evaluate clinical and angiographic outcomes of TAXUS Liberté-SR 2.25 mm stent in de novo lesions versus the TAXUS Express-SR stent. The hypothesis is that the TAXUS Liberté-SR stent has non-inferior safety and efficacy to the TAXUS Express-SR stent in the treatment of de novo lesions in small coronary vessels. The second control group consists of a subset of lesion-matched TAXUS V patients treated with either a 2.5 mm or a 2.25 mm bare metal Express stent. The objective of this analysis is to evaluate clinical and angiographic outcomes of TAXUS Liberté-SR 2.25 mm stent in de novo lesions versus the Express bare metal stent. The hypothesis is that the TAXUS Liberté-SR stent has superior safety and efficacy to the Express bare metal stent in the treatment of de novo lesions in small coronary vessels.

Enrollment

261 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion and exclusion criteria

General Inclusion Criteria:

  1. Patient is at least 18 years old.
  2. Eligible for percutaneous coronary intervention (PCI)
  3. Documented stable angina pectoris or unstable angina pectoris with documented ischemia, or documented silent ischemia
  4. Left ventricular ejection fraction (LVEF) of at least 25%
  5. Acceptable candidate for coronary artery bypass grafting (CABG)
  6. Patient or legal guardian understands the study requirements and the treatment procedures and provides written Informed Consent before any study-specific tests or procedures are performed
  7. Willing to comply with all specified follow-up evaluations

Angiographic Inclusion Criteria:

  1. Only one lesion (target lesion) may be treated with the study stent.However, one additional lesion in a non-target vessel may be treated during the index procedure with a commercially avaiable bare metal stent, heparin-coated stent or TAXUS Express stent.
  2. Successful predilation is mandatory for entry into study
  3. Target lesion located within a single native coronary artery
  4. Target lesion enrolled for treatment may be composed of multiple lesions (not more than 10mm between diseased segments) but must be completely covered by one study stent.
  5. Cumulative target lesion length is greater than or equal to 10 mm and less than or equal to 28 mm (visual estimate)
  6. Target lesion RVD of 2.25 mm [2.2 - 2.5 mm (visual estimate)]
  7. Target lesion diameter stenosis at least 50% (visual estimate)
  8. Target lesion is de novo (i.e., a coronary lesion not previously treated)

General Exclusion Criteria:

  1. Known hypersensitivity to paclitaxel
  2. Any previous, concurrent or planned treatment with a non-study anti-restenotic drug-coated or drug-eluting coronary stent.
  3. Planned use of both the study stent and a non-study stent (i.e., commercial stent) in the treatment of the target vessel
  4. Previous or planned treatment with intravascular brachytherapy in the target vessel
  5. Planned CABG within 9-months post-index procedure
  6. MI within 72 hours prior to the index procedure and/or creatine kinase(CK) >2x the local laboratory's ULN unless CK-MB is <2x ULN
  7. Cerebrovascular Accident (CVA) within the past 6 months
  8. Cardiogenic Shock
  9. Acute or chronic renal dysfunction
  10. Contraindication to ASA, or to both clopidogrel and ticlopidine
  11. Leukopenia
  12. Thrombocytopenia or thrombocytosis
  13. Active peptic ulcer or active gastrointestinal (GI) bleeding
  14. Known allergy to stainless steel
  15. Any prior true anaphylactic reaction to contrast agents
  16. Patient is currently, or has been treated with paclitaxel or other chemotherapeutic agents within 12-months of the index procedure
  17. Anticipated treatment with paclitaxel or oral rapamycin during any period in the 9-months after the index procedure
  18. Male or female with known intention to procreate within 3 months after the index procedure
  19. Female of childbearing potential with a positive pregnancy test within 7 days before the index procedure, or lactating
  20. Life expectancy of less than 24 months due to other medical condition
  21. Co-morbid condition(s) that could limit the patient's ability to participate in the study, compliance with follow-up requirements or impact the scientific integrity of the study
  22. Currently participating in another investigational drug or device study that has not completed the primary endpoint or that clinically interferes with the endpoints of this study

Angiographic Exclusion Criteria:

  1. Unprotected and protected left main coronary artery disease (patient with protected left main disease can be enrolled ONLY if the target lesion is in the RCA)

  2. Target lesion is ostial in location (within 3.0 mm of vessel origin)

  3. Target lesion and/or target vessel proximal to the target lesion is moderately or severely calcified by visual estimate

  4. Target lesion and/or target vessel proximal to the target lesion is tortuous

  5. Target lesion is located within or distal to a >60 degree bend in the vessel

  6. Target lesion involves a bifurcation with a side branch vessel >1.5 mm (visual estimate)

  7. Target lesion is totally occluded (TIMI flow <1), either at baseline or predilation

  8. Angiographic presence of probable or definite thrombus

  9. Pre-treatment of teh target vessel at the index procedure is not allowed with any device except for predilation with balloon angioplasty or cutting balloon

  10. A previously treated lesion within the target vessel:

    • <15mm from the target lesion (visual estimate)
    • Performed </= 6 months from index procedure
    • >30% residual stenosis after previous treatment

Trial design

Primary purpose

Treatment

Allocation

Non-Randomized

Interventional model

Single Group Assignment

Masking

None (Open label)

261 participants in 3 patient groups

Arm 1
Experimental group
Treatment:
Device: TAXUS Liberté-SR
Arm 2
Other group
Description:
Historical Comparator: control data derived from a TAXUS V de novo lesion and stent size-matched cohort randomized to receive a single, planned 2.25 mm DES
Treatment:
Device: TAXUS™ Express2
Arm 3
Other group
Description:
Historical Comparator: control data derived from a TAXUS V de novo lesion size-matched cohort randomized to receive a 2.25 mm or 2.5 mm BMS
Treatment:
Device: Express2

Trial contacts and locations

25

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems