ClinicalTrials.Veeva

Menu

A Study on M2a Magnum Total Hip Arthroplasty

Zimmer Biomet logo

Zimmer Biomet

Status

Completed

Conditions

Avascular Necrosis
Degenerative Joint Disease

Treatments

Device: Total Hip Arthroplasty

Study type

Interventional

Funder types

Industry

Identifiers

NCT01010763
INT.CR.RROW2

Details and patient eligibility

About

The purpose of this study includes the investigation of Metal-ion release and Renal Function analysis in M2a Total Hip Arthroplasty.

Full description

There are no clinical studies conducted on its performance in Asian population. Furthermore clinical data is required to support marketing and validate design of M2A Magnum.

Enrollment

184 patients

Sex

All

Ages

20+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Patients suitable for primary Total Hip Replacement
  • Patients aged over 20
  • Patients with limited co-morbidity- ASA I-III
  • Patients must be able to understand instructions and be willing to return for follow-up
  • Patients willing to provide blood and urine samples for metal ion analysis at follow-up

Exclusion criteria

  • Pre-existing metal implants
  • Infection, sepsis, and osteomyelitis
  • Uncooperative patient or pt with neurologic disorders who are incapable of following directions
  • Osteoporosis
  • Metabolic disorders which may impair bone formation
  • osteomalacia
  • distant foci of infections which may spread to the implant site
  • rapid joint destruction, marked bone loss or bone resorption apparent on roentgenogram
  • vascular insufficiency, muscular atrophy, or neuromuscular disease
  • pregnancy

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

184 participants in 2 patient groups

M2a Magnum
Experimental group
Description:
Total HIp Arthroplasty using with the M2a Magnum Large Metal Articulation is an ultra-high performance metal-on-metal articulation with a big ball (greater than or equal to 38mm) in acetabulums as small as 44mm.
Treatment:
Device: Total Hip Arthroplasty
M2a Taper
Active Comparator group
Description:
Total Hip Arthroplasty using with the M2a Taper Acetabular System consists of a titanium outer shell with cobalt chromium (Co-Cr-Mo) metallic liner, which articulates with with a cobalt chromium (Co-Cr-Mo) modular femoral head.
Treatment:
Device: Total Hip Arthroplasty

Trial documents
1

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2025 Veeva Systems