ClinicalTrials.Veeva

Menu

Ablation Strategies for Persistent Atrial Fibrillation Combined With Heart Failure

Q

Qianfoshan Hospital

Status

Enrolling

Conditions

Atrial Fibrillation
Heart Failure

Treatments

Procedure: 2C3L
Procedure: VOM ethanol chemical ablation and 2C3L

Study type

Interventional

Funder types

Other

Identifiers

NCT06438692
05949801

Details and patient eligibility

About

(1) To evaluate the efficacy and safety of "2C3L" strategy combined with VOM anhydrous ethanol chemical ablation for persistent atrial fibrillation complicated with heart failure; (2) To evaluate the effectiveness of high-efficiency ablation of atrial fibrillation complicated with heart failure.

Full description

2C3L ablation strategy: The electroanatomical mapping system was the Carto 3 V6 system of Johnson & Johnson, and the high-density mapping electrode (Pentaray) and cold saline perfusion pressure catheter (ST-SF) were used for ablation. Ablation parameters were set as follows: ablation power of 45 to 50 Watts (reduced to 25 Watts in the coronary vein and 35 Watts in the endocardium of the mitral isthmus), upper temperature limit of 43 ° C, and saline infusion rate of 15 mL/ min (changed to 30 mL/min in coronary veins), the pressure was controlled at 5-15 g, and the target AI was set: 480-500 for the anterior wall of the pulmonary vein, 350-380 for the posterior wall, 450 for the top of the left atrium, 600 for the mitral valve isthmus, and 450 for the tricuspid valve isthmus. A single catheter procedure was performed in the left atrium, and the ablation endpoint was to achieve continuous bilateral circumferential pulmonary vein damage with loss of intrapulmonary vein potential, which was further confirmed after conversion to sinus rhythm. During left pulmonary vein ablation, the top and posterior wall of left pulmonary vein were ablated first. If pulmonary vein isolation was achieved, no further intervention was performed on the anterior edge of left pulmonary vein. The ablation of the mitral annulus started from about 1 cm away from the junction between the VOM and the coronary vein, and continued to the low-voltage area. Ablation was performed in the corresponding epicardium, namely the coronary vein. Finally, the isthmus of the tricuspid valve was ablated from 6:00 to the inferior vena cava. If the patient still had atrial fibrillation or atrial flutter after the above ablation, 200 J direct current was used to cardioversion the sinus rhythm, and the complete block of each ablation path was verified by pacing during sinus rhythm. In the ablation-only group, catheter ablation was used only to these end points. The operation time was from the start of venipuncture to the removal of sheath tube. The melting time was the cumulative ablation time.

VOM absolute ethanol chemical ablation: The SL1 long sheath was delivered to the opening of the coronary sinus through the right femoral vein, and the right coronary finger guide tube (JR4) was placed to the opening of the coronary sinus. The guide tube was rotated clockwise, and the tip of the guide catheter was pointed in the posterior-superior direction under the right anterior oblique 30 degree fluoroscopy. The BMW guide wire was sent to the proximal end of VOM, and the OTW balloon was sent to the middle and distal end of VOM. The balloon was expanded, and after the BMW guide wire was removed, the course of VOM and whether there was regurgitation were observed by angiography to ensure the complete occlusion of VOM. Anhydrous ethanol was injected in fractions via the OTW balloon.

Enrollment

130 estimated patients

Sex

All

Ages

18 to 80 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  1. age:18y-80y
  2. First ablation on non valvular atrial fibrillation
  3. Persistent atrial fibrillation with LVEF≤40%
  4. The patient has symptoms related to atrial fibrillation, including but not limited to palpitations, premonitory syncope, syncope, fatigue, and shortness of breath, and is evaluated for clinical cardiac function between NYHA II-IV levels
  5. No response to antiarrhythmic drugs, unacceptable side effects, or unwillingness to take antiarrhythmic drugs.

Exclusion criteria

  1. Paroxysmal atrial fibrillation
  2. Atrial fibrillation secondary to obvious reversible causes
  3. Echocardiography: Parasternal long axis section, left atrial diameter ≥ 60mm
  4. LVEF >40%
  5. Receiving dual antithrombotic therapy
  6. Contraindications to the use of oral anticoagulants
  7. Contraindications to right or left cardiac catheterization
  8. pregnancy
  9. Life expectancy<1 year (such as advanced malignant tumors, advanced kidney disease, etc.)
  10. Unable to discontinue antiarrhythmic drugs due to reasons other than atrial fibrillation

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Triple Blind

130 participants in 2 patient groups

2C3L group
Sham Comparator group
Description:
Ablation Procedure:2C3L
Treatment:
Procedure: 2C3L
2C3L-plus group
Experimental group
Description:
Ablation Procedure:2C3L combined with Marshall ethanol ablation
Treatment:
Procedure: VOM ethanol chemical ablation and 2C3L

Trial contacts and locations

1

Loading...

Central trial contact

Xinran Li; Hesheng Hu

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems