The vagus nerve is a nerve that controls many bodily functions, including stomach function. Investigators hope that electrically stimulating the nerve around the external ear will also stimulate the internal vagus nerve. If it does, then investigators hope that this may lead to additional treatment options for patients with nausea and vomiting and disordered stomach function.
The overall purpose of the ABVN Phase 2 grant is to expand on previous work evaluating the effects of noninvasive stimulation on vagal nerve function. This will be accomplished through several independent, but related, studies. In this study, investigators will evaluate autonomic responses in Ehlers-Danlos Syndrome patients and healthy participants during transcutaneous electrical stimulation of the vagus nerve and during normal daily activities.
Full description
Both healthy volunteer subjects and patients with Ehlers-Danlos Syndrome (EDS) will be recruited for this project. Following the first in-person study visit, study participation will last approximately 4 weeks.
When participants arrive for Visit 1, subjects will complete several questionnaires and be trained on the use and care of the wearable watch/bracelet device. They will then wear the bracelet in clinic during Visit 1.
They will then be fitted with:
Two small disc electrodes placed in the auricle of the left ear, fixed by a plastic armature that wraps around the ear. The leads from the electrodes are connected to a stimulator. Electrical stimulation of the electrodes placed in the ear is provided by a current-constant stimulator. The stimuli consist of rectangular pulses with 450 µs pulse width, delivered at 30 Hz, and pulse train duration of 0.5 seconds. Stimulation is gated, and delivered only during the expiratory phase of respiration.
A pneumatic belt will be placed around the lower thorax. Pneumatic tubes connect this belt to a pressure transducer that measures changes in chest diameter during breathing and sends signal to a laptop-controlled device.
ECG electrodes are placed on:
A baseline recording of vagal nerve activity will be made (recording will last for at least 5 minutes). During the baseline recording, no current is delivered to the ear.
At the completion of the baseline recording, electrical stimulation will be sent to the ear electrodes at an intensity which should not cause pain. The current will be increased and decreased by 10 percent for 60 seconds until a comfortable level of sensation has been reached. Once the comfortable level of sensation has been identified (target level), the stimulation will be delivered for a total of 2 minutes. A post-stimulation recording will be made for 5 minutes. Then, an additional stimulation period of 2 minutes may occur, after which, an additional 5 minute post-stimulation recording will be made. Following completion of the final post-stimulation recording, Visit 1 is concluded.
Participants will be instructed to wear the watch at most, if not all, times for the next 4 weeks. The watch can be removed for charging and during showers but should be worn the rest of the time, even during sleep. Participants will be telephoned once weekly (Day 8, 15, and 22) to ask about any issues with the watch, to ensure that data is getting transmitted, and to ensure that no technical issues have developed. The final visit (Day 30) can be completed in person or by phone. At that time, participants will complete the study questionnaires and return the watch (either in person or by mail).
Enrollment
Sex
Ages
Volunteers
Inclusion and exclusion criteria
Inclusion Criteria healthy volunteers
Exclusion Criteria healthy volunteers:
Inclusion Criteria EDS subjects:
Exclusion Criteria for EDS subjects:
Primary purpose
Allocation
Interventional model
Masking
58 participants in 2 patient groups