Accuracy Assessment of an Automatic Blood Pressure Measurement Device in Pregnant Women

W

William Marsh Rice University

Status

Completed

Conditions

Pre Eclampsia

Treatments

Device: Sphygmo

Study type

Interventional

Funder types

Other

Identifiers

NCT02319174
14-082F-B

Details and patient eligibility

About

The purpose of the study is to help make a lower cost automatic blood pressure monitor device for diagnosis and monitoring of pre-eclampsia in pregnant women, where automatic blood pressure monitoring is limited or not available. The study will compare this low cost device to a commercially available system used for pre-eclamptic women in many United States hospitals that the investigators will be bringing to Malawi as a part of this study.

The team hopes to show that this lower cost blood pressure machine works well and can help women with pre-eclampsia. The study also aims to see if this machine is easy for the nurse to use.

70 pregnant women who are either at-risk or diagnosed with pre-eclampsia will be enrolled at University of Texas Health Science Center Houston. Patient arm circumference will be measured with measurement tape.

They will be seated upright in a comfortable chair with arm at heart level and an arm blood pressure cuff from either the automatic blood pressure monitor or a manual sphygmomanometer will be placed on the left arm.

The cuff will be inflated and then deflated until measurement concludes. Heart rate will be measured with tactile arterial palpation.The process will be repeated for a total of up to nine measurements, alternating between measurements with the automatic blood pressure monitor and the manual sphygmomanometer. There will be a waiting period of 45-60 seconds between each measurement.

The results of this study will help researchers understand the performance and usability of this device in Malawi and help decide if any design changes are needed.

Full description

The research team has developed an automatic blood pressure monitor to be used for the monitoring and diagnosis of pre-eclampsia in pregnant women, particularly in low-resource settings where current monitoring is limited. This study aims to evaluate the accuracy of the device's blood pressure measurements in pregnant and pre-eclamptic women. This device must be evaluated with the above described population because blood pressure measurement devices are known to perform differently in pregnant and pre-eclamptic women than in normal healthy adults.

This study will take place at the University of Texas Health Science Center (UTHSC) where up to 70 subjects will be recruited to participate during their regularly scheduled antenatal care checkups.

  1. The Patient arm circumference will be measured with measurement tape.
  2. The Patient will be seated upright in a comfortable chair with arm at heart level.
  3. An arm blood pressure cuff from either the automatic blood pressure monitor or a manual sphygmomanometer will be placed on the left arm of the patient over the brachial artery.
  4. Cuff will be inflated to ~200 mmHg and then deflated until measurement concludes.
  5. Heart rate will be measured with Tactile Arterial Palpation.
  6. Steps 3-4 will be repeated for a total of up to nine measurements, alternating between measurements with the automatic blood pressure monitor and the manual sphygmomanometer. There will be a waiting period of 45-60 seconds between each measurement.

Enrollment

43 patients

Sex

Female

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Pregnant women receiving antenatal care at the UT OB/GYN clinic.
  • Over the age of 18

Exclusion criteria

  • Women under the age of 18
  • Women unable to provide informed consent

Trial design

Primary purpose

Device Feasibility

Allocation

N/A

Interventional model

Single Group Assignment

Masking

None (Open label)

43 participants in 1 patient group

Sphygmo
Experimental group
Description:
All subjects will have blood pressure measured by both the research device (Sphygmo) and the commercially available device. All clinical decisions will be made using measurements from the commercially available device.