Accuracy, Feasibility and Acceptance of CGM Lupus

Shanghai Jiao Tong University logo

Shanghai Jiao Tong University

Status

Unknown

Conditions

Critical Illness
Diabetic Blood Glucose Monitoring
Systemic Lupus Erythematosus

Treatments

Device: Flash glucose monitoring system

Study type

Interventional

Funder types

Other

Identifiers

NCT03296995
SHRJ001

Details and patient eligibility

About

This is a prospective monocenter, non-randomised, open-lable single-group intervention diagnostic trial on the accuracy, reliability and feasibility of the continuous glucose monitoring system in critically systemic lupus erythematosus (SLE). Newly developed technologies for continuous glucose monitoring in critically SLE patients may improve glycemic control and reduce glucose variability. Critically SLE patients will be performed by continuous glucose monitoring. The subcutaneous glucose will be continuously monitored in critical SLE patients by freestyle libre glucose monitoring system for 14 days. The aim of this study is to evaluate accuracy feasibility and acceptance of these methods. To analyze accuracy sensor glucose levels will be validated due to venous blood measurements with glucose oxidase methods. The influence of several factors like oedema, perspiration, BMI, body temperature, pH-value application of vasoconstrictors on accuracy and feasibility of the particular system would be evaluated. Furthermore the acceptance of physicians and Nursing staff would be evaluated by a questionnaire.

Enrollment

30 estimated patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Systemic lupus erythematosus (SLE), as defined by meeting at least 4 of 11 classification criteria of American College of Rheumatology for the classification of systemic lupus erythematosus, either sequentially or coincidentally. The 4 criteria doesn't need to be present at the time of study enrollment;
  • critically SLE patients
  • informed consent by the patients or legal proxy

Exclusion criteria

  • age < 18
  • no informed consent by the patients or legal proxy
  • pregnancy
  • infaust prognosis

Trial design

Primary purpose

Screening

Allocation

N/A

Interventional model

Single Group Assignment

Masking

None (Open label)

30 participants in 1 patient group

flash glucose monitoring system
Experimental group
Description:
Subjects in the arm measure blood glucose by flash glucose monitoring system.
Treatment:
Device: Flash glucose monitoring system