ClinicalTrials.Veeva

Menu

Aerobic Exercise During Hemodialysis

U

Universidade Católica de Pelotas

Status

Unknown

Conditions

Kidney Failure, Chronic

Treatments

Other: Aerobic exercise with cycle ergometer during hemodialysis

Study type

Interventional

Funder types

Other

Identifiers

Details and patient eligibility

About

The aim of this study is to evaluate the effect of aerobic exercise during dialysis on the hemodialysis efficacy in the removal of small molecules measured by continues spend sampling of dialysate (liquid metabolites produced by the body which is disposed) technique.

Full description

This is a controlled clinical trial with participants recruited from the dialysis unit of a university hospital (a tertiary-care centre). All patients from this unit who agreed and that had no medical contraindications had already been included in a resistance and aerobic intradialytic training program. In this unit, the size of the low flux polysulfone dialyzers is selected according to patient's body surface area and the dialyzers are reused up to twelve times. The target Kt/V is 1.2 or higher. The target hemoglobin level is from 10.5 to 12.5 g/dL. Dialysis is performed using On-Line Clearance Monitor (OCM)-equipped Fresenius 4008-S machines (Fresenius, Bad Homburg, Germany).

Design: Patients are included in a randomly crossover study design such that each patient receives one HD session with exercise (intervention) and the next session without exercise (control), alternating for six consecutive HD sessions. The blood flow is maintained at around 300mL/minute and the dialysate flow at 500mL/minute. The dialysate calcium concentration used is 3.0 mEq/L. A new dialyzer is used in the first HD session of each patient at the study, and the dialyzer is reprocessed and reused up to 12 times according to its priming in subsequent sessions. During every HD session continuous spent sampling of dialysate is obtained. The study began in August 2010.

Interventions - Participants underwent hemodialysis sitting in a reclining chair. They trained on an Equimond© mechanically braked cycle ergometer, which we positioned and stabilized in front of the participants while they sit in their chairs during hemodialysis. The training is performed in the first 2 hours of hemodialysis, with a total exercise time of 60 minutes. Each exercise period of 20 minutes is separated by 10 minutes of rest. The patients are advised to work with a level of perceived exertion of 'somewhat strong' (13-14 of Borg scale). For safety, heart rate and blood pressure is monitored throughout the session. The training is terminated if the patients exceeded 80% of their maximum heart rate (MHR = 220 - age in years), blood pressure parameters are exceeded (above 200/110 or below 110/50mmHg) or the patient had chest pain, severe dyspnea, wheezing, leg cramps, confusion, visual symptoms, pallor or cyanosis. Training is conducted by physiotherapists.

Data Collection - Age, gender, skin color, time since starting dialysis therapy and co-morbidity are recorded at baseline. Each patient's hemoglobin level, hematocrit, blood pressure, body mass index (kg/m2) are noted at the beginning and end of the study period. Serum concentration of urea, creatinine, potassium and phosphate are obtained before, after, and 30 minutes after each HD session. The dialysate concentration of urea, creatinine, potassium and phosphate and Kt/V estimated by OCM were obtained during each HD session. The laboratory analyses are conducted by a technician blinded to allocation groups. The OCM measures the difference in conductivity between the dialysate that is coming in and out of the dialyzer and gives an estimated value of Kt/V.

Enrollment

28 patients

Sex

All

Ages

15 to 90 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

The participants of the study were chronic kidney disease patients on hemodialysis for more than 3 months, with a thrice-weekly, for 4 hours and using arteriovenous fistula. The inclusion criteria were residual diuresis less than 500 mL/day; hemodynamic stability during HD treatment (hypotension episodes in <15% of the sessions); good vascular access allowing a blood flow rate greater than 250 mL/min; a hemoglobin level greater than 9.0 g/dL, able to keep sitting and standing balance and walk without assistance, and to be already participating in the exercise program during dialysis.

Exclusion criteria

Exclusion criteria were the use of catheter as venous access, symptomatic ischemic heart disease, myocardial infarction less than 6 months, uncontrolled hypertension, pleural or pericardial friction rub, aortic stenosis.

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Crossover Assignment

Masking

Single Blind

28 participants in 2 patient groups

Hemodialysis session with exercise
Experimental group
Description:
Patients were included in a randomly crossover study design such that each patient received one HD session with exercise (intervention) and the next session without exercise (control), alternating for six consecutive HD sessions.
Treatment:
Other: Aerobic exercise with cycle ergometer during hemodialysis
hemodialysis session without exercise
No Intervention group
Description:
Each patient received one hemodialysis session without exercise

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov