ClinicalTrials.Veeva

Menu

AL-2 MP-1 (Polyimide) Acetabular Liner

M

M.M.A Tech

Status

Unknown

Conditions

Congenital Dysplasia of the Hip
Osteoarthritis
Post-traumatic; Arthrosis
Injury of Hip
Avascular Necrosis
Ankylosing Spondylitis
Rheumatoid Arthritis

Treatments

Device: MP-1 Polymer on Ceramic Articulation system

Study type

Interventional

Funder types

Industry

Identifiers

Details and patient eligibility

About

M.M.A.TECH Ltd. product is an Acetabular Liner Family produced of an advanced polyimide - MP-1™.

M.M.A.TECH Ltd. produces the Liners according to EN ISO 13485:2012 approved manufacturing process and supplies them to the customer.

The aim of this study is to evaluate, in the frame of PMCF, the safety and performance of using AL-X MP1 Polyimide Acetabular liners in Total Hip Replacement surgery by clinical following up of patients for a period of 2 years .

Full description

The procedure involves removal of the diseased parts of the joint, that is the damaged cartilage and adjacent bone, and replacing them with artificial parts which closely resemble in structure and/or function the removed native parts.

The artificial parts fit onto the reshaped bone and are fixed either with bone cement (e.g., polymethylmethacrylate) and press fit of the part(cemented), or by self-anchorage with bone ingrowth to its porous surface(cementless).

The design of the artificial parts may include a stem, a keel or pegs, which fit onto the medullary canal of the bone or into a hole pre-prepared in the bone. An artificial part may fit loosely and be fixed with bone cement, press-fit for self- anchorage or include extendible anchors which are retracted upon placement and extended thereafter so as to secure the implant in place.

Following fixation of the components, the joint is reduced and the soft tissue tension is appropriately checked to reassure stability of the joint.

The MP-1™ acetabular liner will be tapper locked in acetabular metal shells to resurface the acetabular socket in cementless total hip replacement.

MMaTech Ltd will manufacture the liners to perfectly fit into the external metallic shell of the following sizes (mm):

LINER CUP SIZE LINER SIZE HEAD Liner thickness AL-2MP132040 44-48 32 ID 40 OD 32 4 mm AL-2MP136044 50-54 36 ID 44 OD 36 4mm AL-2MP136048 56-66 36 ID 48 OD 36 6mm AL-2MP140048 56-66 40 ID 48 OD 40 4mm

The MP-1™ Acteabular liners are intended to be used only against ceramic femoral heads- Biolox Delta

Enrollment

50 estimated patients

Sex

All

Ages

21 to 90 years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

The inclusion criteria for subject participation in the study are:

(Patient must meet all of the following characteristics to be enrolled in the study):

  • Males and females, 21 to 90 years of age, inclusive;
  • Primary diagnosis of non-inflammatory arthritis (osteoarthritis) or inflammatory arthritis (rheumatoid arthritis), or patients requiring a revision as specified previously;
  • The patient or his/her legal guardian is willing to consent to participate in the study by signing and dating the approved consent form;
  • The patient will be available for follow-up through at least two years postoperative;
  • The patient has met an acceptable preoperative medical clearance and is free or treated for cardiac, pulmonary, hematological, etc., conditions that would pose excessive operative risk (FDA requirement);
  • The patient has a total Harris Hip Score of less than or equal to 60 (FDA requirement);
  • The patient meets none of the exclusion criteria.

Exclusion criteria

with any of the following characteristics must be excluded from the study):

  • Patients known to have insufficient quantity or quality of bone support resulting from Conditions such as cancer, femoral osteotomy, Girdlestone resection, significant osteoporosis or metabolic disorders of calcified tissues. Patients with physical conditions tending to place extreme loads on implants such as morbid obesity (> 100 pounds over desirable body weight), Charcot joints, muscle deficiencies, or multiple joint disabilities;
  • Patients with active localized or systemic infection;
  • Patients who have not reached full skeletal maturity;
  • Patient has had a total knee arthroplasty of either leg
  • Patient psychological or neurological conditions which tend to preempt the patient's ability or willingness to restrict activities or follow medical advice, especially during the postoperative period, e.g.: drug or alcohol abuse, serious mental illness or retardation, or general neurological conditions;
  • The patient is participating in any other pharmaceutical, biologic or medical device clinical investigation;
  • Immunosuppressive disorders - immunosuppressive disorders are chronic conditions characterized by markedly inhibited ability to respond to antigenic stimuli. Examples of such conditions include patients who are on immunosuppressive therapy (corticosteroid hormones in large amounts, cytotoxic drugs, antilymphocytic serum or irradiation in large doses), patients receiving therapy to prevent homograft rejection, patients who have acquired immunodeficiency syndrome (AIDS), or auto-immune diseases (except rheumatoid arthritis).
  • Pregnancy.
  • Patients with known sensitivity to materials in the device.

Trial design

Primary purpose

Treatment

Allocation

N/A

Interventional model

Single Group Assignment

Masking

None (Open label)

50 participants in 1 patient group

Polymer on Ceramic
Experimental group
Description:
MP-1 Polymer on Ceramic articulation system
Treatment:
Device: MP-1 Polymer on Ceramic Articulation system

Trial contacts and locations

1

Loading...

Central trial contact

Simha Sibony

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems