Status
Conditions
Treatments
About
This cross design study will be conducted to evaluate the combination of palpation and auscultation techniques as an alternative technique for the measurement of blood pressure. The main questions it aims to answer are:
Full description
As a result of clinical observations, a common practice is to inflate the cuff to a high and random mmHg value and start auscultation directly. Alternatively, many healthcare workers determine the moment when pulse beats disappear by palpation and increase this value by 30 mmHg without lowering the cuff and without taking a break for 1-2 minutes and start auscultation. In the literature, there is a similar technique called "one-step method". According to this technique, the sphygmomanometer is wrapped around the individual's arm and the stethoscope is placed in the ear. The brachial artery is then palpated and identified. The cuff is inflated up to 30 mmHg above the systolic blood pressure of the individual. The cuff is then depressurized to 2-3 mmHg/second. It is observed that many healthcare professionals and students use this technique today because it is more practical in terms of measurement time. However, it is thought that the step of "inflating the cuff up to 30 mmHg above the systolic blood pressure value of the individual" in the process steps of the technique is not reliable enough. It is thought that it may lead to erroneous results in capturing sudden blood pressure changes in the individual. In this context, it is thought that it would be more reliable to determine the value at the moment when the pulse is not felt with the palpation technique, add 30 mmHg to this value without interruption and without lowering the cuff and continue auscultation. At the same time, combining palpation and auscultation and continuing them consecutively will shorten the measurement time and provide a practical application.
It is aimed to measure blood pressure in approximately 202 healthy adults. The purpose and method of the study will be explained in detail to all participants included in the sample group. Participants will be allowed to rest for 15-30 minutes before blood pressure measurement. Blood pressure will be measured with two different techniques according to the order in which the participants are included in the study. The first participant's blood pressure will first be measured with the standard technique in the literature (with a break between palpation and auscultation). After a 60-second pause, blood pressure will be measured with the alternative recommended technique (palpation and auscultation combined). In the second participant, blood pressure will be measured first with the alternative recommended technique (combining palpation and auscultation). After a 60-second break and with the arm in the same position, blood pressure will be measured with the standard technique in the literature (with a break between palpation and auscultation). The cross-over method will be applied as possible differences between measurement times should be taken into account.
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Exclusion criteria
Primary purpose
Allocation
Interventional model
Masking
202 participants in 2 patient groups
Loading...
Data sourced from clinicaltrials.gov
Clinical trials
Research sites
Resources
Legal