The assessment of muscular function, quality and ability is of high importance in a diverse range of clinical disciplines from anaesthetics to physiotherapy. This study will look at the range of measurement techniques currently in use and development and considers their effectiveness and objectivity. It will also investigate whether an objective measurement technique can be found or developed that can be used both in the clinical environment and the community setting. This will focus on upper limb function and ability; ability is used here instead of strength since ability better describes functions needed for daily living rather than the maximum output a muscle is capable of.
Full description
A literature review (available on request) explores what can be measured, the problems of measurement and its objectivity. The aim is to investigate whether there is a method of measuring muscle quality, function and ability that can be used objectively in the clinical environment or the community with equal ease or whether such a method can be developed.
The literature review identified electrical impedance myography (EIM) as a potentially objective technique to measure muscle quality and ability. Two hypotheses are proposed to test the objectivity:
The EIM measurement of passive and active muscle is not significantly different.
EIM measurements in younger and older adult volunteers is significantly different.
There is only one study visit for this study, so all study activities will occur on the same day at the Posture and Mobility Centre, Treforest or the Artificial Limb and Appliance Centre, Rookwood Hospital.
Eligibility for the study will be checked against the inclusion and exclusion criteria, including the requests to not have done heavy exercise for an hour before the measurements and also to have emptied their bladder before attending for the visit.
Any concerns will be also be addressed appropriately
Following the eligibility check, the CI will ensure the participant has read the PIS and fully understand it before obtaining informed consent.
Participants will be assigned a number in order to anonymise their data and only the main investigator will have access to this database of participants.
The following data will then be collected by the CI and written in a Case Report Form (CRF):
The CI will then attach electrodes to the arm of the participant and they will be asked to relax for 10 minutes.
The measurement device is an ImpediMed IMP SFB7 (CE 0129 marked) and is portable. EIM passes an imperceptible AC current (less than 1 mA) through the muscle under investigation and the impedance of that muscle is then recorded through a range of frequencies or at chosen frequencies.
Measurements of EIM of the relaxed muscles will be recorded in the CRF followed by measurements of EIM in the contracted muscle.
Electrodes will be carefully removed from the participant and they are invited to relax for a further 5 minutes and have a drink of water.
The participant's involvement in the study will end after the measurements have been taken.