ClinicalTrials.Veeva

Menu

An Isolation Device to Contain Aerosol During Aerosol Generating Procedures in the Operating Room

J

John Shin

Status

Completed

Conditions

Aerosol Generating Procedure
Aerosol Containment

Treatments

Device: Novel isolation device to contain aerosol

Study type

Interventional

Funder types

Other

Identifiers

NCT04864236
21-000022

Details and patient eligibility

About

The purpose of this study is to test the safety and efficacy of a new isolation device to contain aerosol during aerosol-generating procedures in the operating room.

Full description

Patients with SARS-CoV-2 infections may require procedures that generate infectious aerosols (suspension of tiny particles or droplets in the air). Aerosols are believed to be the primary method of spread of SARS-CoV-2, as well as many other communicable diseases. In the health care setting, the providers who are in close proximity to patients during these aerosol-generating procedures (ie. Intubation (tube in your throat to help you breathe), noninvasive positive pressure ventilation (breathing support administered through a face or nasal mask) methods such as continuous positive airway pressure (CPAP) or bilevel positive airway pressure (BiPAP), bronchoscopy (thin tube through nose or mouth into the lungs), high flow nasal cannula (oxygen delivery through the nose at a very high flow rate)) are at risk for becoming infected with SARS-CoV-2. The current standard of care to prevent the spread of virus to health care workers involves the use of N-95 respirators (particulate filtering facepiece respirators), which have been intermittently in short supply throughout the current COVID-19 pandemic. In addition, even when there are adequate supplies of N-95 respirators, health care workers have been reusing the respirators multiple times, which may result in decreased efficacy and potential viral exposure. In order to provide enhanced protection to health care workers during aerosol-generating procedures, the study investigators have created a device, named SLACC (Suction-assisted Local Aerosol Containment Chamber). SLACC has the ability to isolate the atmosphere around the patient's upper airway (nose, mouth, throat) via negative pressure in a manner analogous to isolation rooms used to house patients with communicable diseases spread by aerosol (e.g. tuberculosis). Furthermore, SLACC is inexpensive, portable, and relatively simple to manufacture.

The SLACC uses an external suction source to maintain a negative pressure micro-atmosphere around a patient's head (the source of infectious aerosols). The components of SLACC include a clear polymer frame, a flexible drape, and integrated sealed arm sleeves to protect the hands and forearms of the health care provider. The structure is flexible during use, transparent, can be rapidly assembled, and easily collapsible for removal and transport. It is assembled using adhesive-backed polymer sections, allowing the structure to fold from a flat shipping/storage conformation into a free-standing structure. Once deployed with the patient's head inside the chamber, the drape is secured across the open side of the chamber with adhesive and covers the patient's torso. Many other containment devices have been proposed during the COVID-19 pandemic, but none have been demonstrated to contain aerosols effectively. With external suction applied, the investigators believe SLACC vastly improves upon the aerosol containment ability of other devices. The investigators have tested SLACC in a simulated setting and recently published the results in a high-quality, peer-reviewed journal (PMID: 32541251).

The investigators propose to test the safety and efficacy of SLACC in containing contamination during aerosol-generating procedures in the operating room through a randomized controlled trial. The investigators have identified a method of objectively quantifying health care worker exposure to respiratory particles and plan to compare exposure to the number and size of respiratory particles when SLACC is used compared to the current standard of care (no device used).

Enrollment

79 patients

Sex

All

Ages

18+ years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  • Elective scheduled surgery (not emergent)
  • Planned general anesthesia requiring intubation

Exclusion criteria

  • Patients refusing or unable to consent for any reason, including claustrophobia or inability to cooperate
  • Patients predicted to require the use of fiberoptic bronchoscopy for intubation

Trial design

Primary purpose

Other

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

79 participants in 2 patient groups

Intervention group
Experimental group
Description:
This group will undergo airway management in the operating room as part of the anesthesia for surgery in the presence of the novel isolation device.
Treatment:
Device: Novel isolation device to contain aerosol
Control group
No Intervention group