ClinicalTrials.Veeva

Menu

Analyze Changes in Respiratory Rate When Using the Scare Respirator (RESPSUS)

P

Pontificia Universidad Catolica de Chile

Status

Completed

Conditions

Apnea of Newborn
Preterm Labor

Treatments

Device: scare ventilator at 40
Device: No intervention
Device: scare ventilator at 20

Study type

Interventional

Funder types

Other

Identifiers

NCT04584814
180926007

Details and patient eligibility

About

Pilot study of 10 preterm, who are going to be randomly placed to 3 phases : 2 hour of basal observation of respiratory rate, heart rate, saturation, NIPS and aEEG recording, 2 hours with a 20cycles/minute with "scare ventilator", and 2 hours of 40 cycles/minute with "scare ventilator"

Full description

With this pilot study the investigator's want to see if the "scare respirator" can modify the vital signs of the newborn (NB) and if there is a relationship according to the frequency per minute given by the scare respirator and the patient's respiratory rate.

The "scare respirator" has been used many times to prevent central apnea in the newborn. This involves using a mechanical ventilator, but instead of connecting it to the patient's trachea to inflate his lungs, the air flow is connected to a surgical glove that inflates and deflates, with the optimal respiratory rate that the patient should have. This will be placed on the back to stimulate it tactically giving the necessary impulse of inspiration so that the patient alone can acquire the movement.

The importance of the development of this study is that it has been seen that the "scare respirator" could avoid central apneas, but no studies have been done on the change in respiratory rate that occurs with the device or if it bothers the NB or alters its wakefulness sleep pattern.

It is intended to evaluate 10 premature infants, during 3 observation periods. Heart rate (HR), Respiratory rate (RR) and saturation, pain scale and aEEG sleep wake pattern will be evaluated; first a rest period between feeds as baseline, then with a scare respirator at 20 cycles per minute and finally at 40 cycles per minute. The differences of qualitative and quantitative variables will be assessed with ad-hoc statistical tests.

Enrollment

10 patients

Sex

All

Ages

1 day to 1 month old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  • hospitalized healthy preterm babies,
  • weighing more than 1500g at the time of the study

Exclusion criteria

  • babies receiving any respiratory support
  • carrier of any mayor malformation or genetic condition

Trial design

Primary purpose

Treatment

Allocation

N/A

Interventional model

Sequential Assignment

Masking

None (Open label)

10 participants in 1 patient group

Babies born Preterm
Experimental group
Description:
Preterm babies, healthy at the time of the study, free of neonatal diseases and/or sequelae or malformations or genetic diseases. They were random assigned to two-hours blocks of basal, and dorsal stimulation protocol at 20 or 40 times per minute, each.
Treatment:
Device: scare ventilator at 20
Device: scare ventilator at 40
Device: No intervention

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location