Aortic Root Enlargement Versus Aortic Root Replacement in the Management of Cases With Small Aortic Root

A

Assiut University

Status

Unknown

Conditions

Aortic Valve Disease

Treatments

Procedure: Aortic valve surgery

Study type

Observational

Funder types

Other

Identifiers

NCT05167539
Aortic valve surgery

Details and patient eligibility

About

Each type of Aortic valve surgery has its advantages and disadvantages; we aim to differentiate between two types of aortic valve surgery: aortic root replacement (using either Ross procedure or stentless bioprosthesis procedure) and mechanical aortic valve replacement.

Full description

Aortic valve replacement has been performed since the 1950s. Since then, the surgical procedure has been optimized to reduce the risk of procedure-related complications. In addition, technical advances in the design of valves have significantly improved long-term prognosis. After the initial use of mechanical ball-caged valves, numerous monoleaflet and bileaflet valves have been introduced and evaluated. Moreover, bioprosthetic valves came on the market in the 1960s as an alternative to mechanical valve.

The pulmonary autograft was introduced in clinical practice as a substitute for the diseased aortic valve by Donald Ross in 1967. The original implant technique, namely subcoronary freehand grafting, was associated with substantial prevalence of early and late valve dysfunction, thereby limiting widespread adoption of the operation. More recent experience with pulmonary autografts used for complete or partial aortic root replacement allowed for satisfactory functional behavior of the valve .

Homografts for aortic valve replacement were the first biologic stentless prostheses used in clinical practice in the 1960s. Binet introduced a stentless porcine bioprosthesis, but the valve was abandoned because of poor tissue fixation. Due to limited availability and a relatively difficult implantation technique, mechanical AVR became the popular therapeutic option. The disadvantage of life-long anticoagulation therapy in mechanical AVR prompted the development of xenogeneic bioprostheses. Although porcine aortic valves or pericardial tissue mounted on a stent made the implantation technique easier, these valves sacrificed orifice area and increased stress at the attachment of the stent, which caused earlier primary tissue failure. Optimizing hemodynamics to prevent patient-prosthetic mismatch and improve durability revived the use of stentless bioprostheses in the early 1990s.

Patients with an expected survival of less than 10 years (more than 65 years old, renal disease, lung disease, patients who are more than 60 years old), ejection fraction of less than 40%, or coronary disease would be reasonable candidates for aortic bioprostheses to avoid anticoagulation with an extremely low likelihood of aortic valve reoperation. Results tend to favor mechanical aortic valves in patients under age 65 years with a life expectancy of at least 10 years.

Enrollment

100 estimated patients

Sex

All

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Patients undergoing Aortic valve surgery.

Exclusion criteria

  • Patients who have other procedure with aortic valve surgery.

Trial design

100 participants in 2 patient groups

Mechanical aortic valve replacement
Description:
simple procedure but need long term of anticoagulant
Treatment:
Procedure: Aortic valve surgery
Aortic root replacement
Description:
complicated procedure but without anticoagulant
Treatment:
Procedure: Aortic valve surgery