ClinicalTrials.Veeva

Menu

Application of Radiostereometric Analysis (RSA) to Triathlon Knee Components Inserted Using the OtisMed Custom-fit Total Knee Replacement System

D

Dalhousie University

Status

Completed

Conditions

Osteoarthritis

Treatments

Procedure: OtisMed
Procedure: Computer Assisted Surgery (CAS)

Study type

Interventional

Funder types

Other

Identifiers

NCT01262430
CDHA-RS/2011-296

Details and patient eligibility

About

The OtisMed Custom-fit system for total knee replacements replaces conventional surgical techniques for templating and intra-operative instrumentation with a preoperative virtual surgery process that utilizes 3D models of the affected knee from a pre-operative MRI or CT image. The 3D model of the affected knee is processed with a proprietary algorithm that virtually alters it to its pre-arthritic state by filling articular defects, removing osteophytes, and approximating the joint surface. The software then shape matches the knee replacement femoral and tibial components to the preathritic knee model and aligns the femoral component to the functional flexion-extension axis of the femur. The final preoperative step is the machining of custom biocompatible plastic cutting blocks that fit the arthritic knee. These cutting blocks are used during the knee replacement surgery to guide the bone cuts so that the replacement components are aligned for the individual patient.

In this study we propose to compare patients who have received total knee replacement components with the OtisMed Custom-fit procedure to those who have had the same components implanted in the conventional manner with Computer Assisted Surgery (CAS). The primary outcome will be micromotion of tibial and femoral implants at 1 and 2 years after surgery. Secondary outcomes will include subjective outcomes, accelerometric gait analysis, bone mineral density, full leg alignment, change in intra-operative frontal plane alignment, intra-operative deviations from the surgical plan, surgery duration, OR turnover time, number of instrument pans used, and length of hospital stay.

Full description

Knee and hip arthroplasty are profoundly successful operative interventions, however, some joint replacements do fail and the life expectancy of a knee or hip arthroplasty is finite. This fact has largely been responsible for the continued development of new devices and techniques for joint arthroplasty surgery.

The OtisMed Custom-fit technique has great potential to shift knee replacement surgery to a more patient-specific paradigm. Existing studies with OtisMed surgeries have found a reduced need for soft-tissue releases, alignment comparable to conventional and computer navigated surgery, reduced tourniquet time, and reduced instrumentation. Although the preliminary results are promising the OtisMed Custom-fit system is still unproven, with no long-term follow-up studies completed to date. An initial report has questioned the effectiveness of the procedure although it is a very limited series of four surgeries. To definitively determine if the technique is an improvement on conventional knee arthroplasty a randomized controlled trial with high-resolution quantitative assessment of outcomes is clearly called for.

Question 1: Is there a difference in micromotion patterns for implant components between CAS and the OtisMed knee system?

  • Null Hypothesis: There are no significant difference in micromotion patterns.
  • Alternative Hypothesis: There are significant differences in micromotion patterns between the tibial and/or femoral components.

Question 2: Do the CAS knee components achieve adequate fixation to the underlying bone?

  • Null Hypothesis: There is no significant continuous migration of the tibial and femoral components at 2 years indicating adequate long-term fixation at the implant - bone interface.
  • Alternative Hypothesis: There is significant continuous migration of the tibial and/or femoral components at 2 years indicating inadequate fixation at the implant - bone interface.

Question 3: Do the OtisMed knee components achieve adequate fixation to the underlying bone?

  • Null Hypothesis: There is no significant continuous migration of the tibial and femoral components at 2 years indicating adequate long-term fixation at the implant - bone interface.
  • Alternative Hypothesis: There is significant continuous migration of the tibial and/or femoral components at 2 years indicating inadequate fixation at the implant - bone interface.

Question 4: For what proportion of implants in each group does migration continue to increase during the two year follow-up?

Question 5: Are inducible displacements, measured during loaded follow-up exams, different between the 2 groups?

Question 6: Are there significant differences in bone mineral density between the operative knee (proximal tibia) and other body sites over time?

Question 7: Are there significant differences in bone mineral density of the proximal tibia between the OtisMed and CAS groups over time?

Question 8: Is there a significant difference in gait symmetry measures, health status and functional outcome between the OtisMed and CAS groups?

Question 9: Is there a significant difference in postoperative full-leg length alignment between the CAS and OtisMed groups?

Question 10: Are there significant differences in the frontal plane alignment curves obtained from the CAS system between the CAS and OtisMed groups?

Question 12: Are there significant differences in the quantity of bone resection between the CAS and OtisMed groups?

Question 13: Are there significant differences in the frontal plane alignment curves obtained from the CAS system between the CAS and OtisMed groups?

Question 14: Are there significant differences in the number of intra-operative deviations from the surgical plan between the CAS and OtisMed groups?

Question 15: Is there a significant difference in the duration of surgery (tourniquet time) between the CAS and OtisMed groups?

Question 16: Is there a significant difference in the number of instrument pans used between the CAS and OtisMed groups?

Question 17: Is there a significant difference in length of hospital stay between the CAS and OtisMed groups?

Question 18: Are there intra-patient differences between the OtisMed surgical plan and the CAS surgical procedure in terms of predicted versus actual resection and alignment?

Enrollment

52 patients

Sex

All

Ages

21 to 80 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  1. Symptomatic osteoarthritis of the knee indicating surgical intervention
  2. Between the ages of 21 and 80 inclusive
  3. Ability to give informed consent

Exclusion criteria

  1. Significant co-morbidity affecting ability to ambulate
  2. Flexion contracture greater than 15°
  3. Extension lag greater than 10°
  4. Tibial subluxation greater than 10 mm on standing AP radiograph
  5. Prior arthroplasty, patellectomy or osteotomy with the affected knee
  6. Lateral or medial collateral ligament instability (> 10° varus/valgus)
  7. Leg length discrepancy greater than 10 mm
  8. Pregnancy
  9. Active or prior infection
  10. Morbid Obesity (BMI > 40)
  11. Medical condition precluding major surgery
  12. Severe osteoporosis or osteopenia
  13. Neuromuscular impairment

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Double Blind

52 participants in 2 patient groups

OtisMed
Active Comparator group
Treatment:
Procedure: OtisMed
Computer Assisted Surgery (CAS)
Active Comparator group
Treatment:
Procedure: Computer Assisted Surgery (CAS)