Status and phase
Conditions
Treatments
About
This will be a randomized prospective and open-label study with no placebo control or blinding of the participants and the research team members. The study is to compare the effectiveness of vaginal progesterone versus combination of vaginal progesterone and Arabin cervical pessary in the prevention of preterm delivery among patients with incidental shortened cervical length.
As part of standard clinical care, all pregnant patients usually have cervical length measurements at the mid-trimester during the anatomy scan from 18 to 24 weeks with the GE ultrasound Volusion 8 using the vaginal probe.
Full description
Preterm birth is the leading cause of neonatal mortality and disability in survivors in the United States. Short cervical length measured by transvaginal ultrasound has been strongly associated with an increased risk of preterm birth. Vaginal progesterone has been proposed as a management option to reduce the risk of preterm birth in asymptomatic women with singleton gestations without prior preterm birth with a very short cervical length. Short cervix in this population is defined as less than or equal to 20 mm, when measured between 18 and 24 weeks.
The American College of Obstetrics and Gynecology (ACOG) and the Society of Maternal Fetal Medicine (SMFM) have proposed the use of vaginal progesterone either micronized progesterone capsule, 200mg daily, or vaginal progesterone gel, 90 mg daily, in asymptomatic women carrying a singleton pregnancy and an incidental finding of short cervix.
Cervical length is usually measured at time of routine anatomical survey fetal between 18 and 24 weeks of gestation for the prevention of preterm birth at less than 37 weeks.
Furthermore, cervical pessary has been used in the prevention of preterm birth for many decades in a few studies with promising results. More recently, the Arabin pessary has been designed with the sole purpose of prevention of preterm birth in pregnant patients with short cervix. It is relatively noninvasive, not operator-dependent and can be easily placed and removed in the outpatient setting.
The purpose of this study is to test the hypothesis that adding the use of the Arabin pessary for women identified with short cervix and undergoing the standard of care treatment with vaginal progesterone, further decreases the risk of preterm birth.
This will be a prospective randomized trial using vaginal progesterone alone compared with the combination of vaginal progesterone and Arabin pessary in the prevention of preterm delivery among women who are incidentally found to have short cervical length. Patients diagnosed with short cervical length with no prior history of preterm deliveries during routine mid-trimester screening will be enrolled in this study and will be randomized into two groups. One group will be given vaginal progesterone only, which is the current standard of care in the United States. The second group will receive Arabin cervical pessary, to be inserted in the clinic at the time of diagnosis, in addition to daily vaginal progesterone.
Vaginal progesterone will be 200 mg or 90 mg of Crinone inserted once daily at bedtime in both groups, depending on patients' insurance coverage. The participants of the study will be followed up in the high risk obstetric clinic as per standard clinic surveillance. They will receive the standard prenatal care and treatment when warranted according to their clinic conditions.
Hypothesis:
The use of Arabin pessary in conjunction with the standard treatment of vaginal progesterone is more effective in reducing preterm deliveries at less than 37 weeks in women identified with short cervix in mid trimester without other risk factors.
Primary Objective:
Secondary objectives:
4.0 Eligibility
Participants will be recruited from the investigators' clinical practice if they are diagnosed with short cervical length equal or less than 20 mm at routine ultrasound screening for cervical length during mid-trimester anatomy scan from 18-24 weeks at the UIC ultrasound units. Those with cervical length less than or equal to 20 mm will be randomized (1:1) into two arms: the vaginal progesterone only group and the combined vaginal progesterone and Arabin cervical pessary group. Those with cervical lengths between 20 mm to 25 mm will be followed up in 1 week with repeat transvaginal sonogram, according to the unit protocol but they will be randomized to either group only if they are diagnosed with shorter cervical lengths of 20 mm or less prior to 24 weeks of gestation.
4.1 Inclusion Criteria
4.2 Exclusion Criteria
4.3 Excluded or Vulnerable Populations
Patients who do not have capacity to give consent will be excluded from the study. Women under the age of 18 will not be enrolled in this study.
5.0 Subject Enrollment
6.0 Study Design and Procedures
To review, standard prenatal clinical care at UIC includes a cervical length ultrasound evaluation at the time of the routine anatomical fetal survey between 18-24 weeks. When an incidental finding of shortened cervical length is made, patients are typically prescribed vaginal progesterone. They are then followed at the high-risk OB clinic every 2 weeks until delivery. This randomized prospective study compares standard clinical care (vaginal progesterone alone) to standard care plus the Arabin pessary (vaginal progesterone + Arabin cervical pessary) in the prevention of preterm delivery in pregnant women incidentally found to have a significantly shortened cervix between 18 and 24 weeks.
This will be a randomized prospective and open-label study with no placebo control or blinding of the participants and the research team members. The study is to compare the effectiveness of vaginal progesterone versus combination of vaginal progesterone and Arabin cervical pessary in the prevention of preterm delivery among patients with incidental shortened cervical length.
As part of standard clinical care, all pregnant patients usually have cervical length measurements at the mid-trimester during the anatomy scan from 18 to 24 weeks with the GE ultrasound Volusion 8 using the vaginal probe.
Studies involving use of product
This study uses the Arabin cervical pessary and vaginal progesterone (Endometrin 200 mg or Crinone 90 mg gel).
Arabin cervical pessary:
This is a tissue tolerant non-allergic silicone ring plastic device with a cup-like shape used for cervical insufficiency. It comes in various sizes and it is classified according to its size:
The lower larger diameter (65 or 70 mm) The height (17, 21, 25 or 30 mm) The upper small diameter (32 or 35 mm)
The Arabin cervical pessary can easily be folded and inserted in the upper vaginal around the cervix without pain. The majority of the patients receive a device size of 32 mm of the upper diameter, 21 mm for height and 65 mm for lower diameter. However, participants with significantly funneling of the cervical canal will receive a device of 35 mm of the upper diameter while those with previous vaginal deliveries will receive a device with lower diameter of 70 mm. The length of the vaginal component of the cervix will determine the height of the Arabin pessary to be inserted. Before the applications, participants will be screened and treated for any cervical or vaginal infections. All participants will be screened for bacterial vaginosis, candida infection and Trichomonas, and positive tests will receive appropriate treatments, as per standard of care.
The proposed Arabin cervical pessary will be: Vaginal pessary, CE 0482 MED CERT, EN ISO 13485. Center for Research and Development. Alfred-Herrhausen Str. 44 D 58455 Witten, Germany. Phone: +49 2 302 / 189214. The device will be given to every participant randomized to the pessary group free of charge.
Vaginal pessaries have been used for many years in gynecology for non-surgical treatment of utero-vaginal prolapse and stress urinary incontinence. Different types of pessary based on the indication and the pelvic anatomical defect have been used. Some of the pessaries that have been used in gynecology include: ring, ring with support, Gehrung, Gellhorn, Shaatz, Donut, Cube and inflatable. Vaginal pessaries like Donut and ring with support have been used in pregnancy for the management of cervical insufficiency. However, the pitfall in the use of these pessaries is that they are easily expelled due to the anatomical changes of the vagina in pregnancy that make it difficult for them to fit well in the vagina. With the introduction of Arabin cervical pessary which is designed to allow it wrap around the cervix instead of just placing it in the vagina negate this pitfall. Arabin cervical pessary have been used for many years in Europe for the prevention of preterm delivery in women with cervical incompetence. A Cochrane review by Abdel -Aleem in 2013 showed that Arabin cervical pessary has beneficial effects in reducing preterm birth in women with short cervix, (Abdel-Aleem et al 2013, Liem S et al 2013 and Ting YH et al 2012). This is a non-invasive, and not operator-dependent silicone plastic that is inserted in the vagina to wrap around the cervix thereby preventing it from shortening and dilating. It can easily be placed or removed in an outpatient clinic and it does not require anesthesia. It does not need to be removed for examinations. Premature cervical shortening and dilatation is one of the most important causes of preterm birth. This device does not have systemic adverse effects and the only complaints reported by some of the users is slightly increase vaginal discharge. In another study of systematic review of the efficacy of Arabin cervical pessary, it showed that majority of the patients; > 90 % expressed great satisfaction with the device and they will recommend it to other patients (Sophie M et al 2013).
Endometrin or Crinone vaginal progesterone (Ferring Reproductive Health):
Endometrin (progesterone vaginal insert) is a vaginal insert containing 100 mg of micronized progesterone. Crinone is a vaginal gel (8%) with 90 mg of micronized progesterone. Progesterone is a natural hormone that is often used in pregnancy for various indications. One of the indications is for prevention of preterm deliveries in women with short cervical length. It is usually well tolerated except for some minor side effects such as allergic reactions to some of its components, itching, headache or flushing.
7.0 Expected Risks/Benefits
The expected risks include:
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Exclusion criteria
Primary purpose
Allocation
Interventional model
Masking
57 participants in 2 patient groups
Loading...
Data sourced from clinicaltrials.gov
Clinical trials
Research sites
Resources
Legal