ClinicalTrials.Veeva

Menu

Assessment of the Efficacy and Safety of a DYnaMic Peripheral DegradatiON Myopia Disorder Control in Myopic Children ״DYMOND Study״

N

NovaSight

Status and phase

Enrolling
Phase 2

Conditions

Myopia

Treatments

Device: TrackSight

Study type

Interventional

Funder types

Industry

Identifiers

NCT07390500
NS-01317

Details and patient eligibility

About

The DYMOND study evaluates the safety and effectiveness of TrackSight™, a digital medical application designed to slow myopia (nearsightedness) progression in children during everyday screen use. TrackSight uses eye-tracking technology to keep central vision clear while subtly adjusting the image in the peripheral viewing area, based on established scientific principles known to influence eye growth.

Up to 150 children aged 6 to 12 with myopia will participate at sites in Israel and Hong Kong. All participants will continue wearing their regular single-vision glasses and will be randomly assigned to use TrackSight with or without active visual adjustment for 12 months. Eye examinations and safety assessments will be conducted at the start of the study and after 6 and 12 months. The study aims to determine whether this non-invasive digital approach can safely slow myopia progression in children.

Full description

The DYMOND study is a clinical research study designed to evaluate the safety and effectiveness of a digital application called TrackSight™ for slowing the progression of myopia (nearsightedness) in children. Myopia often worsens during childhood, particularly during activities that involve prolonged screen use, such as studying, gaming, or watching videos. This study explores whether a software-based approach can help reduce the rate of myopia progression during everyday screen use.

TrackSight™ is a software medical device that uses real-time eye-tracking technology to subtly adjust the visual information presented on a digital screen. While central vision remains clear at all times, the software applies controlled visual changes to the peripheral areas of the screen. These changes are designed to influence how the eye grows, based on established scientific principles that have been shown to slow myopia progression in studies using special spectacle and contact lenses. TrackSight delivers these same principles digitally, without altering standard vision correction.

Up to 150 children between the ages of 6 and 12 with mild to moderate myopia will participate in the study at clinical sites in Israel and Hong Kong. All children will continue wearing their regular single-vision glasses throughout the study. Participants will be randomly assigned to one of three study groups. Two groups will use TrackSight with different active visual adjustment settings, while one group will use the same application with these features turned off. Neither the families nor the study staff will know which version of the software a child is using during the study.

Children will use the TrackSight application during their normal screen activities over a period of 12 months. Eye examinations will be performed at the start of the study and again at 6 and 12 months to measure changes in eye growth and vision. Questionnaires will be used to assess screen use, vision-related quality of life, and overall experience with the software. Safety will be closely monitored throughout the study, and families will have access to technical support if needed.

The primary goal of the study is to determine whether TrackSight can safely slow the progression of myopia by reducing eye growth over one year compared with no active treatment. The results of this study may help support a new, non-invasive digital approach to managing childhood myopia in modern screen-based environments.

Enrollment

150 estimated patients

Sex

All

Ages

6 to 12 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Aged 6-12 years

    -. Diagnosed with myopia: cycloplegic spherical or spherical equivalent (SER) between -0.75D and -5.00D, astigmatism ≤ -1.50D, anisometropia < 1.50D

  • Visual acuity 20/32 or better (age-appropriate testing) in both eyes

  • Interocular VA difference ≤1.00 logMAR line

  • Subject in general good health and able, as per investigator decision, to comply with study visits and protocol procedures

  • The subject is using digital devices for at least 1 hour/day regularly according to parental report

  • Signed informed consent by legal parent/guardian and assent approval -. Currently wearing single vision refractive correction

Exclusion criteria

  • Past or concurrent use of any other myopia treatment (e.g., atropine, orthokeratology, myopia control glasses/lenses)
  • Eye diseases or abnormality, developmental conditions, or past ocular surgeries or any other condition which could potentially affect refraction or AL progression according to the investigator's judgement
  • Current or prior history of manifest strabismus, amblyopia, or nystagmus
  • Subject cannot pass eye tracking calibration in at least 50% of cases, or cannot be tracked in at least 50% of the time during a screening eligibility test
  • Current or previous use of bifocal lenses, progressive-addition lenses, or multi-focal contact lenses
  • Premature gestational age ≤32 weeks or birth weight <1500g.

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Quadruple Blind

150 participants in 3 patient groups

TrackSight™ with active peripheral image degradation (blur)
Experimental group
Description:
Participants use TrackSight™ with active peripheral image degradation enabled using combination #1 during their normal screen activities. Central vision remains clear while the peripheral image is digitally modified. Standard single-vision glasses are worn at all times.
Treatment:
Device: TrackSight
rackSight™ with active peripheral image degradation (contrast)
Experimental group
Description:
Participants use TrackSight™ with active peripheral image degradation enabled using combination #2, which applies a different level or pattern of visual modification during screen use. Central vision is unaffected, and standard single-vision glasses are worn throughout the study.
Treatment:
Device: TrackSight
TrackSight™ with the peripheral image degradation function disabled (control).
Sham Comparator group
Description:
Participants use the same TrackSight™ software and device, but the peripheral image degradation feature is disabled. Screen use and standard single-vision glasses remain unchanged, serving as the control condition.
Treatment:
Device: TrackSight

Trial contacts and locations

1

Loading...

Central trial contact

Oren Yehezkel, PhD

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems