Attenuation Corrected Cardiac SPECT Using the GE Hawkeye Camera System

Mayo Clinic logo

Mayo Clinic

Status and phase

Terminated
Phase 3
Phase 2

Conditions

Cardiac Disease

Treatments

Device: GE Attenuation Corrected Hawkeye Camera

Study type

Interventional

Funder types

Other

Identifiers

NCT00587730
1042-01

Details and patient eligibility

About

The accuracy of stress single photon emission computed tomography (SPECT) is limited by imaging artifacts, many of which are caused by soft tissue attenuation. A recent multicenter study performed by our laboratory comparing 7 commercially available attenuation correction (AC) camera systems in a cardiac phantom showed the best performance with the GE Hawkeye (a hybrid gamma camera-CT scanner) and the University of Michigan M-step (unique feature a camera orbit of 360˚ versus the usual 180˚) systems. In this study we will combine the strengths of these two systems (GE Hawkeye AC system and 360˚ camera orbit) to test the accuracy of this imaging system in a population of 400 consecutive patients undergoing clinically indicated stress SPECT. These patients will undergo SPECT imaging both with conventional methodology and the GE Hawkeye system. The conventional study will be interpreted and reported in the usual clinical fashion. The GE Hawkeye images will be interpreted independently by 2 observers blinded to the results of conventional imaging and will not be reported clinically. The primary study hypothesis is that AC will substantially reduce attenuation artifacts (mild fixed defects) without reducing the accuracy of either normal studies or myocardial infarction (MI). Clinical data and noninvasive test results (history of MI, electrocardiogram, and gated wall motion) will be used to distinguish defects which represent attenuation (false-positive) versus those due to MI (true-positive).

Enrollment

608 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Patients referred to the Charlton Nuclear Cardiology Laboratory for stress Tc-99m sestamibi SPECT

Exclusion criteria

  • Prior PTCA or CABG
  • Left bundle branch block (LBBB) or paced ventricular rhythm
  • Clinically significant valvular heart disease
  • Hypertrophic or idiopathic dilated cardiomyopathy
  • Atrial fibrillation or frequent atrial or ventricular ectopy (defined as >20% ectopic beats
  • History of MI
  • ECG evidence of MI
  • Chest circumference >55 inches

Trial design

Primary purpose

Diagnostic

Allocation

Non-Randomized

Interventional model

Single Group Assignment

Masking

None (Open label)

608 participants in 1 patient group

Clinical SPECT
Active Comparator group
Description:
GE Hawkeye Attenuation Correction Camera is being compared to the approved clinical use SPECT camera.
Treatment:
Device: GE Attenuation Corrected Hawkeye Camera