Automated Versus Manual Control Of Oxygen For Preterm Infants On Continuous Positive Airway Pressure In Nigeria

M

Murdoch Childrens Research Institute

Status

Completed

Conditions

Prematurity
Neonatal Respiratory Failure
Oxygen Toxicity
Neonatal Respiratory Distress Related Conditions

Treatments

Other: Manual oxygen control
Device: OxyMate

Study type

Interventional

Funder types

Other

Identifiers

NCT05508308
HREC84704

Details and patient eligibility

About

One in ten babies are born preterm (<37 weeks gestation) globally. Complications of prematurity are the leading cause of death in children under 5 years, with the highest mortality rate in Sub-Saharan Africa (SSA). Low flow oxygen, and respiratory support - where an oxygen/air mixture is delivered under pressure - are life saving therapies for these babies. Bubble Continuous Positive Airway Pressure (bCPAP) is the mainstay of neonatal respiratory support in SSA.

Oxygen in excess can damage the immature eyes (Retinopathy of Prematurity [ROP]) and lungs (Chronic Lung Disease) of preterm babies. Historically, in well-resourced settings, excessive oxygen administration to newborns has been associated with 'epidemics' of ROP associated blindness. Today, with increasing survival of preterm babies in SSA, and increasing access to oxygen and bCPAP, there are concerns about an emerging epidemic of ROP. Manually adjusting the amount of oxygen provided to an infant on bCPAP is difficult, and fearing the risks of hypoxaemia (low oxygen levels) busy health workers often accept hyperoxaemia (excessive oxygen levels). Some well resourced neonatal intensive care units globally have adopted Automated Oxygen Control (AOC), where a computer uses a baby's oxygen saturation by pulse oximetry (SpO2) to frequently adjust how much oxygen is provided, targetting a safe SpO2 range. This technology has never been tested in SSA, or partnered with bCPAP devices that would be more appropriate for SSA.

This study aims to compare AOC coupled with a low cost and robust bCPAP device (Diamedica Baby CPAP) - OxyMate - with manual control of oxygen for preterm babies on bCPAP in two hospitals in south west Nigeria. The hypothesis is that OxyMate can significantly and safely increase the proportion of time preterm infants on bCPAP spend in safe oxygen saturation levels.

Full description

Trial description: A randomised cross-over trial of manual versus automated control of oxygen (OxyMate) for preterm infants on bCPAP. This trial will use an established technology (automated oxygen titration algorithm, VDL1.1) partnered with a low-cost bCPAP device in a low-resource setting. It will involve preterm infants requiring bCPAP respiratory support with allocation to OxyMate or manual oxygen control for consecutive 24 h periods in random sequence.

Objectives: This trial seeks to examine safety and potential efficacy of our automated oxygen configuration (OxyMate) in preterm infants in a setting characterised by financial constraints, workforce limitations, and underdeveloped infrastructure, and assess contextual feasibility and appropriateness to inform future definitive clinical trials and product development.

Enrollment

49 patients

Sex

All

Ages

12 hours to 1 month old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • <34 weeks gestation (or birth weight < 2kg if gestation not known)
  • ≥12 hours old
  • Receiving CPAP support and supplemental oxygen (FiO2 >0.21) for respiratory insufficiency
  • Projected requirement for CPAP and oxygen therapy for > 48 hours

Exclusion criteria

  • Deemed likely to fail CPAP in the next 48 hours
  • Deemed clinically unstable or recommended for palliation by treating team
  • Cause of hypoxaemia likely to be non-respiratory - e.g. cyanotic heart disease
  • Informed consent from parent/guardians not obtained

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Crossover Assignment

Masking

None (Open label)

49 participants in 2 patient groups

Manual oxygen control
Active Comparator group
Description:
Oxygen therapy delivered with bCPAP as per standard practice, except for the addition of continuous pulse oximetry. Nursing staff will make manual adjustments to Fraction of Inspired Oxygen (FiO2) provided to infants on bCPAP. Oxygen saturations (SpO2) will be monitored by continuous pulse oximetry, and nurses asked to target the range of SpO2 91-95%. Pulse oximeter alarms will be set to alert nurses to periods of hypoxaemia (SpO2\<88%) and hyperoxaemia (SpO2\>96%).
Treatment:
Other: Manual oxygen control
OxyMate Automated Oxygen Control
Experimental group
Description:
Automated control of oxygen therapy partnered with bCPAP delivered as per standard practice. The automated oxygen control set-up (OxyMate) will consist of: continuous pulse oximetry input, a computer algorithm (VDL1.1) that calculates changes to delivered FiO2 based on the input SpO2, and a mechanism to automatically effect changes to delivered FiO2. The system will target an SpO2 of 93% (mid-point of the target range). There will be several embedded safety mechanisms, including the ability to manually over-ride OxyMate at any stage. Pulse oximeter alarms will be as for the manual control arm, with additional automated system alarms in place.
Treatment:
Device: OxyMate