ClinicalTrials.Veeva

Menu

Automatic Oxygen Titration in Patients After SARS-CoV-2 Infection

S

Schön Klinik Berchtesgadener Land

Status

Completed

Conditions

Post-COVID19

Treatments

Other: Oxygen therapy

Study type

Interventional

Funder types

Other

Identifiers

NCT04849598
O2matic_COVID

Details and patient eligibility

About

With the progression of the SARS-CoV-2 pandemic there's an increasing number of patients recovering from COVID19. Some of these patients still experience hypoxemia and therefore are still in need of a long-term oxygen therapy (LTOT), usually provided as a constant-flow. However, during a patient's daily activities, oxygenation levels may vary and the same constant flow may not be suitable for all tasks. Studies in COPD patients suggest that an automatic oxygen titration, which adjusts the oxygen flow automatically according to a patient's blood oxygen levels to prevent desaturations, could be beneficial compared to a constant oxygen titration during exercise.

So far there are no studies available that directly compare the automatic oxygen titration with the patient's prescribed constant oxygen flow in patients with hypoxemia after SARS-CoV-2 infection during activities of daily life. Therefore, the primary outcome of this study is to investigate the effects of an automatic oxygen titration (O2matic, Denmark) in comparison to constant oxygen flow rates as prescribed according to guidelines.

Full description

Rationale

After an infection with SARS-CoV-2, some patients still experience hypoxemia even after being discharged from the hospital. Long-term oxygen therapy (LTOT) is then used to increase the patients blood oxygen level and prolong the time spent within the SpO2 target range, decreasing the probability of severe hypoxemia or at least lowering the time spent in this severe hypoxemia and all in all enhance the patient's endurance. A prescription for LTOT is usually given for constant flow rates which might vary during day- and night use.

This study is a randomized, controlled cross-over trial. Its aim is to investigate the effects of an automatic oxygen titration in patients after SARS-CoV-2 infection on the blood oxygen saturation level during activities of daily life (walking). Secondary, the effects of using an automatic titration on endurance, pCO2 blood level as well as heart rate and breathing frequency are compared to using the prescribed constant flow oxygen therapy.

Design:

Each patient undergoes a series of shuttle walk tests. After an initial incremental shuttle walk test (ISWT) to determine the patient's maximum walking speed, the patient undergoes 2 endurance shuttle walk tests (ESWTs) at 85% of the maximum walking speed. One of these ESWTs is performed with the prescribed constant oxygen flow, the other with the O2matic automatic oxygen titration in a random order.

In addition to the shuttle walk tests, patient will perform two stair walking tests, again one with the prescribed constant oxygen flow, the other with the O2matic automatic oxygen titration in a random order.

Furthermore, patients will be asked to rate their experienced comfort after each ESWT and to name their preferred oxygen titration system.

Enrollment

15 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • validated COVID19 disease in case history
  • hypoxemia (PO2 < 55 mmHg) under room air conditions (rest or during exercise) or SpO2 <88% during exercise
  • already established Long-term oxygen therapy or given indication for a Long-term oxygen therapy

Exclusion criteria

  • acute infection
  • cardiovascular diseases that limit physical fitness
  • orthopedic diseases preventing the patient from undergoing the walking tests

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Crossover Assignment

Masking

Double Blind

15 participants in 4 patient groups

ESWT Order A and B
Experimental group
Description:
First Endurance Shuttle Walk Test using the automatic oxygen titration (O2matic) with the target range being 90 - 94% SpO2, the second Endurance Shuttle Walk Test using the prescribed constant flow oxygen therapy.
Treatment:
Other: Oxygen therapy
ESWT Order B and A
Experimental group
Description:
First Endurance Shuttle Walk Test using the prescribed constant flow oxygen therapy, the second Endurance Shuttle Walk Test using the automatic oxygen titration (O2matic) with the target range being 90 - 94% SpO2.
Treatment:
Other: Oxygen therapy
Stairs Order A and B
Experimental group
Description:
First Stair Walking Test using the automatic oxygen titration (O2matic) with the target range being 90 - 94% SpO2, the second Stair Walking Test using the prescribed constant flow oxygen therapy.
Treatment:
Other: Oxygen therapy
Stairs Order B and A
Experimental group
Description:
First Stair Walking Test using the prescribed constant flow oxygen therapy, the second Stair Test using the automatic oxygen titration (O2matic) with the target range being 90 - 94% SpO2.
Treatment:
Other: Oxygen therapy

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems