Axial Length and Central Corneal Thickness in Benign Intracranial Hypertension

O

Ochsner Health System

Status

Terminated

Conditions

Benign Intracranial Hypertension

Treatments

Device: Pachette3
Device: Lenstar-Think

Study type

Interventional

Funder types

Other

Identifiers

NCT02541994
2015.002.A

Details and patient eligibility

About

Patients in for treatment of benign intracranial hypertension will undergo two tests that are not routinely performed for these patients: central corneal thickness and axial length of the eye. The data obtained from these measurements will be assessed to see if the correlate with aspects of vision loss including visual acuity, visual field status, optical coherence tomography (OCT) results, and fundus photographs.

Full description

Patients with benign intracranial hypertension would be identified at diagnosis from the general ophthalmic and neurologic patient population in the Ochsner Health System. All would have a baseline eye examination with visual field and optical coherence tomography (OCT) testing, a standard step in managing any patient with this condition. Two measurements would be taken at minimal risk to the patient that they would not normally have done at the baseline exam: central corneal thickness and axial length. These procedures are routinely done on patients with glaucoma, corneal disease, and cataracts without a significant risk of injury. The theoretical risks with central corneal thickness and axial length measurements by A-scan ultrasonography are related to the small risk for transmission of infection or corneal abrasion due to a probe touching the cornea. These tests would be performed at no charge to the patient and would not significantly increase the time of the ocular examination. Patients would have neuro-imaging studies and lumbar puncture to confirm the diagnosis of benign intracranial hypertension as standard parts of the work up for the condition independent of the research study. The authors will statistically analyze the standard measures of visual field function and health of the nerve fiber layer by OCT to see if any or all of the proposed risk factors correlates with deterioration of visual function. Data would continue to be collected at follow up visits related to visual fields and OCT as would normally be performed on standard visits for this condition. The measurements of central corneal thickness and axial length would be performed solely at the time of enrollment in the study since these measurements do not change over time.

Enrollment

5 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Patients must have benign intracranial hypertension.

Exclusion criteria

  • None

Trial design

Primary purpose

Screening

Allocation

N/A

Interventional model

Single Group Assignment

Masking

None (Open label)

5 participants in 1 patient group

Ultrasound Testing
Other group
Description:
Single arm with all patients getting measurements of axial length and central corneal thickness.