ClinicalTrials.Veeva

Menu

BES, EES, and ZES-R in Real World Practice (CHOICE)

Yonsei University logo

Yonsei University

Status

Terminated

Conditions

Coronary Artery Disease

Treatments

Device: Biolimus-eluting stent
Device: Everolimus-eluting stent
Device: Zotarolimus-eluting stent

Study type

Interventional

Funder types

Other

Identifiers

Details and patient eligibility

About

The primary objective of this study is to compare the rate of device-oriented composite consisted of cardiac death, myocardial infarction not clearly attributable to a nontarget vessel, and clinically indicated target lesion revascularization among the patients treated with EES, ZES-R, or BES at 24-month clinical follow-up post-index procedure. Trial end points are summarized in Table I. The hypothesis is that BES is equivalent to EES or BES is equivalent to ZES-R at the primary end point.

Full description

Previous randomized trials have shown the superior efficacy of drug-eluting stents (DES), such as sirolimus-eluting stent (SES, CYPHER, Cordis, US), paclitaxel-eluting stent (PES, TAXUS, Boston Scientific, US), and zotarolimus-eluting stent (ZES, Endeavor, Medtronic, US) compared with bare metal stents (BMS) by reducing neointimal hyperplasia, late luminal loss, and angiographic restenosis leading to decreased target lesion revascularization. Unfortunately, restenosis still occurs and late stent thrombosis can develop by delaying endoluminal healing or by chronic inflammation.Accordingly, development of new DES is required to improve efficacy by reducing revascularization and safety by reducing the risk of stent thrombosis. With the improvement of polymer, drug, and the platform, the 2nd generation DES, including everolimus-eluting stent (EES, Xience V or Xience Prime, Abbott, USA), zotarolimus-eluting stent with biolinx polymer (ZES-R, Endeavor Resolute or Endeavor Resolute Integrity, Medtronic, USA), and biolimus-eluting stent (BES, BioMatrix or Biomatrix Flex, Biosensors, USA), have been shown to be superior or non-inferior in safety and efficacy trials compared with 1st generation DES.

However, it is difficult to know if there are any differences in efficacy and safety between the EES, the ZES-R, and the BES, in real world practice due to the lack of data comparing these three 2nd generation DES directly. This study provides the evidence for the CHOICE of stent when physicians are treating patients by percutaneous coronary intervention.

Enrollment

1,960 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion and exclusion criteria

Inclusion Criteria

  • Age > 19 years
  • Subject is able to verbally confirm understanding of risks, benefits and treatment alternatives of receiving the drug-eluting stent(s) and he/she or his/her legally authorized representative provides written informed consent prior to any study related procedure
  • Subject must have significant stenosis (>50% by visual estimate) on a native or in-stent coronary artery
  • Subject must have evidence of myocardial ischemia (e.g., stable, unstable angina, recent infarction, acute myocardial infarction, positive functional study or a reversible changes in the ECG consistent with ischemia). In subjects with coronary artery stenosis >75%, evidence of myocardial ischemia does not have to be documented

Exclusion Criteria

  • Subject has a known hypersensitivity or contraindication to any of the following medications: heparin, aspirin, clopidogrel, prasugrel, ticagrelor, biolimus A9, everolimus, zotarolimus, stainless steel, cobalt chromium, contrast media (Patients with documented sensitivity to contrast media, which can be effectively premedicated with steroid and diphenhydramine may be enrolled. However, those with true anaphylaxis to prior contrast media should not be enrolled.)
  • Subject in use of systemic (intravenous) biolimus A9, everolimus or zotarolimus within 12 months.
  • Female subject of childbearing potential, unless a recent pregnancy test is negative, who possibly plans to become pregnant any time after enrollment into this study
  • Subject planned an elective surgical procedure that would necessitate interruption of antiplatelet during the first 12 months post enrollment
  • Subject with non-cardiac co-morbid condition with life expectancy < 2 year or that may result in protocol non-compliance (per site investigator's medical judgment)
  • Subject with cardiogenic shock at presentation
  • Subject who are actively participating in another drug or device investigational study, who have not completed the primary end point follow-up period

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Single Blind

1,960 participants in 3 patient groups

Biolimus-eluting stent
Active Comparator group
Description:
Biomatrix stent, Biosensors, USA Biomatrix Flex stent, Biosensors, USA
Treatment:
Device: Biolimus-eluting stent
Everolimus-eluting stent
Active Comparator group
Description:
Xience Prime stent, Abbott, USA Xience V stent, Abbott, USA
Treatment:
Device: Everolimus-eluting stent
Zotarolimus-eluting stent
Active Comparator group
Description:
Endeavor resolute, Medtronic, USA Endeavor resolute integrity, Medtronic, USA
Treatment:
Device: Zotarolimus-eluting stent

Trial contacts and locations

5

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems