ClinicalTrials.Veeva

Menu

Bioresorbable Polymer ORSIRO Versus Durable Polymer RESOLUTE ONYX Stents (BIONYX)

T

Thorax Centrum Twente

Status

Unknown

Conditions

Coronary Artery Disease
Coronary Restenosis
Acute Coronary Syndrome
Unstable Angina Pectoris
Angina Pectoris
Coronary Stenosis

Treatments

Device: Resolute Onyx
Device: Orsiro

Study type

Interventional

Funder types

Other

Identifiers

Details and patient eligibility

About

The introduction of drug-eluting stents (DES) in the treatment of coronary artery disease has led to a significant reduction in morbidity. However, the first generation of these devices had no positive impact on the mortality after PCI (compared to bare metal stents), which was greatly attributed to a somewhat increased incidence of late and very late stent thrombosis. Concerns about the role of durable polymers as a potential trigger of inflammation and finally adverse events also led to the development of DES with bioresorbable coatings, which leave after degradation of the coating only a bare metal stent in the vessel wall that does not induce an inflammatory response. While such bioresorbable polymer DES are increasingly used in clinical practice, data from head-to-head comparisons between bioresorbable polymer DES with a contemporary highly flexible new generation permanent polymer coated DES.

Full description

rationale: The introduction of drug-eluting stents (DES) in the treatment of coronary artery disease has led to a significant reduction in morbidity. However, the first generation of these devices had no positive impact on the mortality after PCI (compared to bare metal stents), which was greatly attributed to a somewhat increased incidence of late and very late stent thrombosis. Concerns about the role of durable polymers as a potential trigger of inflammation and finally adverse events also led to the development of DES with bioresorbable coatings, which leave after degradation of the coating only a bare metal stent in the vessel wall that does not induce an inflammatory response. While such bioresorbable polymer DES are increasingly used in clinical practice, data from head-to-head comparisons between bioresorbable polymer DES with a contemporary highly flexible new generation permanent polymer coated DES.

Aim:

The aim of the study is to compare the outcome of the bioresorbable polymer coated stent (ORSIRO) and a new generation permanent polymer coated stent (RESOLUTE ONYX) in an all-comers patient population and non-inferiority setting.

Study design:

The study is a prospective, randomized, single-blinded, multicentre trial with 1:1 randomization for drug-eluting stent type, stratified for gender and the presence of diabetes mellitus.

Study population:

Patients who require percutaneous coronary intervention (PCI) for the treatment of coronary stenoses with an indication for DES use, according to current guidelines and/or the operators clinical judgement. All clinical syndromes will be included. A total of 2,470 patients will be included.

Intervention:

One group will receive the ORSIRO stent, the other group will receive the RESOLUTE ONYX stent. All other intervention and procedural characteristics are similar.

Primary study outcome:

Incidence of target vessel failure (TVF) at 1 year follow-up (according to ARC definitions). Components of the primary endpoint in hierarchical order: - Cardiac death: all deaths are considered cardiac, unless an unequivocal non-cardiac cause can be established. - Target vessel related myocardial infarction (MI) that is Q-wave or non-Q-wave, that can be related to the target vessel or cannot be related to another vessel. - Clinically driven repeated target vessel revascularization by means of PCI or coronary artery bypass grafting (CABG).

Enrollment

2,470 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Patients of 18 years and older, requiring PCI for the treatment of significant coronary artery or bypass graft lesions, being eligible for treatment with drug eluting stents according to clinical guidelines and/or the operators' judgement, and capable of providing informed consent.
  • Patients with all clinical syndromes will be enrolled without any exclusion based on number, type, location or length of lesions to be treated.

Exclusion criteria

  • Known intolerance to components of one of the study DES, or known intolerance to antithrombotic and/or anticoagulant therapy that prevents adherence to any dual anti-platelet therapy (DAPT).
  • Planned elective surgical procedure necessitating interruption of DAPT during the first 3 months after randomization.
  • Participation in another randomized cardiovascular device trial or randomized pharmacological study related to antithrombotic and/or anticoagulant therapy before reaching the primary endpoint.
  • Known pregnancy, adherence to scheduled follow-up is unlikely, or life expectancy is assumed to be less than 1 year

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Double Blind

2,470 participants in 2 patient groups

Orsiro DES (Biotronik)
Active Comparator group
Description:
The ORSIRO hybrid coating DES (Biotronik, Switzerland) is a device which includes a modern, highly flexible, thin-strut stent platform, eluting sirolimus from a thin biodegradable BIO-lute coating grom PLLA (poly(L-lactic acid)) which is located mainly on the abluminal side.
Treatment:
Device: Orsiro
RESOLUTE ONYX DES (Medtronic)
Active Comparator group
Description:
The RESOLUTE ONYX is a permanent polymer DES that uses a novel highly flexible metallic stent backbone with increased radiographic visibility eluting the drug zotarolimus from the BioLinx durable polymer coating. The stent platform uses corewire technology that allows the stent to have a denser core metal surrounded by outer layer of cobalt-chromium.
Treatment:
Device: Resolute Onyx

Trial contacts and locations

7

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems