Bispectral Index: A Comparison of Bifrontal Montage Agreement

Mayo Clinic logo

Mayo Clinic

Status

Completed

Conditions

Surgery
Bispectral Index

Treatments

Device: BIS sensor

Study type

Observational

Funder types

Other

Identifiers

NCT04062240
19-000568

Details and patient eligibility

About

The researchers are trying to compare the results of two sensors when recorded simultaneously on opposite sides of the forehead.

Full description

Bispectral Index (BIS) monitors are FDA approved to gauge depth of sedation by analyzing segments of electroencephalogram (EEG) waves. The BIS monitor utilizes a proprietary algorithm to process the EEG information second by second, and outputs a number (0-100) that corresponds with a patient's level of consciousness. A level of 0 indicates no EEG activity; a level of 100 indicates awake EEG activity. Several studies demonstrated that BIS monitors may not be useful in paralyzed patients, as patients who were paralyzed and not sedated unexpectedly showed a large decrease in their BIS values following administration paralytic medications. Vivien et al found BIS values dropped an average of 24 points in already sedated patients when the patients were given paralytics. In the same year, Messner and colleagues paralyzed non-sedated volunteers and found a dramatic drop in BIS values until paralysis wore off or was reversed. Schuller et al repeated the Messner experiment and found similar results with 18 of 20 non-sedated volunteer's BIS values dropping to levels expected of patients who were sedated. These results suggest that BIS monitors are integrating electromyography (EMG) data into its algorithm to derive a BIS value. Our hypothesis is that a BIS monitor commenced after paralysis, thereby lacking exposure to any "awake" EMG activity, will result in a cleaner data set and more accurate representation of a patient's level of sedation. Studying in this manner will require the subject to wear two BIS sensors in a frontal montage. The manufacturer of the sensors gives no guidance as to which side of the forehead an individual sensor is placed, and no studies demonstrate BIS validity with the use of concurrent sensors. The purpose of the present investigation is to assess the measurement difference and variability associated with use of concurrent bifrontal BIS sensors. The data obtained will be used as a framework for a future study related to the use of paralytics and BIS monitoring.

Enrollment

15 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  1. Adult patient having elective cardiac surgery

Exclusion criteria

  1. Patient refusal.
  2. Pediatric patients.
  3. Emergency procedure.
  4. Patients with known or suspected carotid or cerebrovascular disease.
  5. Patients with prior stroke.
  6. Skin condition or anatomy preventing proper sensor placement.

Trial design

15 participants in 1 patient group

Additional BIS sensor
Description:
Many providers caring for cardiovascular surgical patients utilizes BIS monitoring to gauge depth of anesthesia. The current practice involves placement of the BIS sensor on the patient's forehead per the manufacturer's recommendation on arrival to the operating room. The intervention in this study will add an additional BIS sensor to the patient's forehead. After syncing the two monitors for time, and ensuring appropriate skin contact and signal quality of both sensors, BIS monitoring will commence. BIS readings will be available every 12 seconds during the duration of the study, yielding up to 240 points of comparison per enrolled patient.
Treatment:
Device: BIS sensor