Status
Conditions
Treatments
About
This study is to further develop and optimise the design and manufacturing process of a handheld device to monitor and manage Warfarin (blood thinning anticoagulation drug) therapy. The device comprises of a handheld instrument and a disposable test strip and reports how blood coagulation is working in terms of standardised units called International Normalised Ratio (INR). A single drop of fresh whole blood and plasma will be added to the strip and the INR result displayed on the instrument. Blood samples are to be collected from patients attending a hospital based INR clinic who are on Warfarin Therapy. The samples are to be used in a series of experiments in the laboratory to test the Microvisk POC INR Monitors accuracy, precision, stability and robustness.
Full description
The number of patients receiving anticoagulation therapy with warfarin and other vitamin K antagonists has been rising in recent years. Increasing life expectancy is increasing the proportion of the population having conditions such as Atrial Fibrillation and venous thrombosis, where primary and secondary prevention of thromboembolic complications are best achieved with anticoagulation.
Unpredictable pharmacokinetics, widespread interactions with drugs and food and the narrow therapeutic window make closely monitoring Vitamin K antagonists a necessity. Portable point of care (POC) coagulometers which measure PT from capillary whole blood and provide an INR reading within a few minutes are already widely available throughout North American and Europe. They give comparable results when compared to laboratory based systems are popular with patients and significantly shorten the duration of clinics. In addition, the United Kingdom Department of Health has been encouraging the use of anticoagulation services in Primary Care Trusts the aim being to provide INR monitoring in community clinics and General Practice surgeries relieving pressure on hospital services and reducing inconvenience for patients.
Although coagulometers are now commercially available the Microvisk INR Testing System has been designed to have advantages, particularly in terms of test robustness, user comfort, ease of use and reduction of user error. The present trial has been designed to develop the second generation Microvisk INR Test System; blood samples will also be used to optimise manufacturing processes and verify the quality of Test Strip Lots.
Enrollment
Sex
Ages
Volunteers
Inclusion criteria
Exclusion criteria
Primary purpose
Allocation
Interventional model
Masking
1,560 participants in 1 patient group
Loading...
Central trial contact
Joseph Booth
Data sourced from clinicaltrials.gov
Clinical trials
Research sites
Resources
Legal