ClinicalTrials.Veeva

Menu

Breath Analysis as an Additional Test for Colorectal Cancer Screening to Reduce the Number of Unnecessary Colonoscopies (SCREENER)

R

Radboud University Medical Center

Status

Completed

Conditions

Colorectal Neoplasms
Polyp of Colon
Colorectal Cancer

Treatments

Device: AeonoseTM

Study type

Interventional

Funder types

Other

Identifiers

NCT04357158
'2020-6184'

Details and patient eligibility

About

In the past decade, the demand for colonoscopy procedures has increased significantly since the introduction of population-based colorectal cancer (CRC) screening in many western countries. Post-polypectomy surveillance will increase the number of colonoscopy procedures conducted each year even further. The invasive nature of colonoscopy and the associated health-care costs warrant the development of a new non-invasive test to reduce the number of unnecessary colonoscopies.

These days, many countries use a non-invasive fecal test for CRC screening which is easy to perform at home, but test characteristics such as sensitivity and specificity are suboptimal. Multiple studies have already shown that volatile organic compound (VOC) analysis has a high diagnostic accuracy for CRC and Advanced Adenomas. An additional VOC analysis, for example through breath testing, in patients with a positive fecal immunochemical test (FIT) may reduce the number of unnecessary colonoscopies.

The aim of this study is to validate the diagnostic accuracy of the AeonoseTM to distinguish patients with CRC from healthy controls, and to assess reproducibility of test results.

Full description

Rationale: An electronic nose (eNose) is an artificial olfactory system that analyses volate organic compounds (VOCs) in exhaled breath. Exhaled human breath is mainly composed of inorganic compounds, inert gases and VOCs. VOCs are exhaled in very low concentrations and reflect pathological processes such as inflammation, oxidation, infection and neoplasms. The perspective is that metabolic and biochemical processes in several pathological situations cause different endogenous VOCs to arise, were they can serve as non-invasive biomarkers for certain diseases.

Primary objective: To evaluate if the use of an additional breath test (AeonoseTM) for patients with a positive FIT-test can reduce the number of unnecessary colonoscopies.

Secondary objectives:

  1. External validation of results for CRC and (advanced) adenoma detection established in a previous studies (second study not yet published). (15)
  2. To evaluate if VOC profiles in breath are similar at two different time points.
  3. Acceptance rate of using the AeonoseTM device for VOC analysis in participating patients.

Study population: Patients between the ages of 55 and 75 years old with a positive FIT-test referred for a colonoscopy procedure.

Estimated sample size: 750 participants

Intervention: Participants will be asked to breath through the AeonoseTM for 5 minutes during pre-colonoscopy intake and just prior to the procedure to assess reproducibility (with >2 weeks in between). There are no risks, nor benefits for the participants.

Enrollment

750 patients

Sex

All

Ages

50 to 75 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Adult patients between the ages of 55 and 75 years referred for a colonoscopy procedure after a positive FIT test, according to the population based CRC screening program in the Netherlands

Exclusion criteria

  • Prior surgical resection of any portion of the colon
  • History of any type of malignancy, not including squamous cell carcinoma (SCC) and basal cell carcinoma (BCC)
  • Current active colitis or history of polyposis syndrome

Trial design

Primary purpose

Diagnostic

Allocation

N/A

Interventional model

Single Group Assignment

Masking

None (Open label)

750 participants in 1 patient group

Patients referred for colonoscopy
Other group
Treatment:
Device: AeonoseTM

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems