ClinicalTrials.Veeva

Menu

CAD/CAM Angle Fracture Reduction/Plate Guide and Customized 3D Grid Plate Versus Champy's Technique

Cairo University (CU) logo

Cairo University (CU)

Status

Enrolling

Conditions

Mandibular Fractures

Treatments

Procedure: Champy's techqniue
Procedure: CAD/CAM patient specfifc fracture reduction/plate guide and customized 3D grid plate

Study type

Interventional

Funder types

Other

Identifiers

Details and patient eligibility

About

This proposed study aims at creating a computer designed patient specific device and titanium plates, that are 3D manufactured in accordance to a preoperative computer aided virtual surgical procedure, aiming to obtain proper alignment of fractured segments of the lower jaw and restore proper teeth positioning therefore overcoming the possible complications of the conventional methods.

Recruited participants will be randomly allocated to a treatment groupp, whether the novel method group or a standard treatment group.

Preoperative panoramic radiograph and a Computed tomography scan will be obtained for each patient.

Surgical procedure will be conducted unde general anesthetic. Medications will be prescribed after surgery and instructions will be given to each patient.

Follow up will be on a weekly basis for the first 6 weeks followed by a followup visit once a month for 6 months.

Postoperative panoramic radiograph and a Computed tomography scan will be obtained at 1 week after the surgical procrdure and again 6 months later.

Digital data obtained from computed tomography scans along with clinical data will be analysed and studied to determine the accuracy of the computer aided device and for comparison with the standard method of treatment.

Enrollment

20 estimated patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  1. Patients with unilateral mandibular angle fracture with or without associated mandibular fractures in need of open reduction and internal fixation.
  2. Patients above 18 years old
  3. Sufficient dentition to reproduce the occlusal relationships
  4. Patient's consent to participate

Exclusion criteria

  1. Patients with comminuted mandibular angle fracture(s)
  2. Patients with any systemic disease that may affect normal healing
  3. Patients undergoing chemotherapy or radiotherapy related to the head and neck region
  4. Intra-bony lesions in the fracture area that may interfere with proper anatomical reduction.

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Double Blind

20 participants in 2 patient groups

Custom made reduction guides and 3D grid plates
Experimental group
Description:
Mandibular angle fracture reduction and fixation using digitally designed and fabricated patient specific fracture reduction/plate positioning guide and customized 3D grid plate
Treatment:
Procedure: CAD/CAM patient specfifc fracture reduction/plate guide and customized 3D grid plate
Stock titanium plates
Active Comparator group
Description:
Mandibular angle fracture reduction and fixation using a single superior border 2.0 miniplate
Treatment:
Procedure: Champy's techqniue

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location