ClinicalTrials.Veeva

Menu

Cardiac Resynchronization in the Elderly

S

Samir Saba

Status

Completed

Conditions

Heart Failure

Treatments

Device: Cardiac Resynchronization Therapy Defibrillator
Device: Cardiac Resynchronization Therapy Pacemaker

Study type

Interventional

Funder types

Other

Identifiers

NCT03031847
PRO17010015

Details and patient eligibility

About

This pilot will enroll 50 HF patients (age ≥ 75 years) undergoing CRT device implantation at the hospitals of the University of Pittsburgh Medical Center, Duke University, Ohio State University, and the VA Pittsburgh Healthcare System. Patients will be randomized to CRT-P versus CRT-D and followed until study end. Rates of patient screening, enrollment, randomization, and retention as well as cost of care will be examined. The results of this pilot study will inform the design of a large pivotal non-inferiority trial and will be necessary for its success. Patients who refuse participation in the randomized pilot trial will be asked to enroll in a prospective observational cohort. Characteristics of patients who choose CRT-P vs. CRT-D will be compared and patients' level of satisfaction with their device decision will be measured.

Full description

The goal of this study is to pilot test a randomized, controlled, non-inferiority trial comparing the survival and quality of life (QOL) of older patients receiving cardiac resynchronization therapy (CRT) pacemaker (CRT-P) versus defibrillator (CRT-D) therapy. This pilot will enroll 50 HF patients (age ≥ 75 years) undergoing CRT device implantation at the hospitals of the University of Pittsburgh Medical Center, Duke University, Ohio State University, and the VA Pittsburgh Healthcare System. Patients will be randomized to CRT-P versus CRT-D and followed until study end. Rates of patient screening, enrollment, randomization, and retention as well as cost of care will be examined. The results of this pilot study will inform the design of a large pivotal non-inferiority trial and will be necessary for its success. Patients who refuse participation in the randomized pilot trial will be enrolled and followed as part of a prospective observational cohort. Characteristics of patients who choose CRT-P vs. CRT-D will be compared and patients' level of satisfaction with their device decision will be measured.

Enrollment

102 patients

Sex

All

Ages

75+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  1. Age >/= 75 years
  2. Left Ventricular Ejection Fraction (LVEF) ≤ 35% by cardiac imaging including echocardiogram, nuclear imaging, cardiac catheterization, or cardiac magnetic resonance imaging
  3. QRS width >120 ms on surface electrocardiogram
  4. New York Heart Association class II, III, or ambulatory IV for Heart Failure (HF)
  5. Patient undergoing de novo CRT device implantation of CRT-D device change-out for battery depletion

Exclusion criteria

  1. Patient within 40 days of acute myocardial infarction
  2. Patient within 3 months of cardiac revascularization (percutaneous coronary intervention or bypass surgery)
  3. Patient with prior history of cardiac arrest or documented sustained ventricular arrhythmia
  4. Patient with expected longevity < 1 year
  5. Patient not on optimal medical therapy for HF management including when tolerated β-blockers, angiotensin converting enzyme inhibitors or angiotensin receptor blockers
  6. Patient not planning to have his/her follow-up at participating institution
  7. Patient unable or unwilling to sign a written informed consent
  8. Patient's with dementia that are unable to consent for themselves
  9. Participating in any other clinical trials (observational/registries allowed)

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

102 participants in 4 patient groups

Randomized- Pacemaker (CRT-P)
Other group
Description:
Cardiac resynchronization therapy Pacemaker
Treatment:
Device: Cardiac Resynchronization Therapy Pacemaker
Randomized- Defibrillator (CRT-D)
Other group
Description:
Cardiac resynchronization therapy Defibrillator
Treatment:
Device: Cardiac Resynchronization Therapy Defibrillator
Observational- Pacemaker (CRT-P)
Other group
Description:
Cardiac resynchronization therapy Pacemaker (CRT-P): Patients in this arm declined randomization in the trial and elected to participate in the observational registry
Treatment:
Device: Cardiac Resynchronization Therapy Pacemaker
Observational- Defibrillator (CRT-D)
Other group
Description:
Cardiac resynchronization therapy Defibrillator (CRT-D): Patients in this arm declined randomization in the trial and elected to participate in the observational registry
Treatment:
Device: Cardiac Resynchronization Therapy Defibrillator

Trial documents
1

Trial contacts and locations

6

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems