ClinicalTrials.Veeva

Menu

Cardiac Resynchronization Therapy (CRT) Based Heart Failure Monitoring Study (zLAP)

Abbott logo

Abbott

Status

Completed

Conditions

Heart Failure

Treatments

Device: Cardiac Resynchronization Therapy
Device: HeartPOD™ System

Study type

Observational

Funder types

Industry

Identifiers

NCT00632372
60015786

Details and patient eligibility

About

The purpose of this study is to collect and analyze electrical measurements, timing, and signals from a CRT-D device in heart failure patients who either already have an implanted left atrial pressure sensor or will undergo a simultaneous implantation of a left atrial pressure sensor and a CRT-D device. These devices may be placed at the same time or separately (staged procedure) at the discretion of the investigator. A comparison will be made between the information gathered from the CRT-D system and the information gathered by the left atrial pressure sensor.

Full description

This is a multi-center feasibility study.

.

Enrollment

8 patients

Sex

All

Ages

18 to 85 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Age > 18 and ≤ 85.
  • Have an approved indication per ACC/AHA/HRS guidelines for implantation of a CRT-D. Alternatively, the patient may already have in place an existing Promote CRT-D or other SJM CRT device with similar functions, or have a CRT-D device that requires a generator change. In addition, the patient may be already enrolled in HOMEOSTASIS I or II and completed the 12-month follow-up.
  • Central venous vascular access.
  • Have a legally marketed right atrial bipolar pacing lead, a right ventricular bipolar defibrillation lead, and a left ventricular bipolar pacing lead.
  • Demonstrate capability of Valsalva maneuver with airway pressure > 40 mm Hg for ≥10 seconds.
  • The subject and the treating physician agree that the subject is geographically stable and willing to comply with all required post-procedure follow-up, and that the patient is capable of correct device use as outlined in the protocol.
  • The subject has been informed of the nature of the study and agrees to its provisions and has provided written informed consent as approved by the Institutional Review Board or Ethics Committee of the respective clinical site

Exclusion criteria

  • Intractable HF with resting symptoms despite maximal medical therapy (AHA/ACC Stage D) or active listing for cardiac transplantation (<6 months survival expected).
  • Resting systolic blood pressure < 90 or > 180 mm Hg.
  • Acute Myocardial Infarction (MI), unstable ischemic syndrome within the last 6 weeks.
  • Percutaneous coronary intervention (PCI) or cardiac surgery performed or planned within ± 6 weeks.
  • Coexisting stenotic valve lesions, vegetations, hypertrophic cardiomyopathy, amyloidosis or other infiltrative heart disease, constrictive, restrictive disease, tamponade, or moderate or large pericardial effusion.
  • Subject has a history of deep venous thrombosis or pulmonary embolism within the last 6 months.
  • Surgical correction of congenital heart disease involving atrial septum that will prevent safe implantation of the SJM HeartPOD ISL.
  • Cerebral Vascular Accident (CVA) or Transient Ischemic Attacks (TIA's) within the last 6 months. History of uncorrected cerebral vascular disease.
  • Atrial or ventricular thrombus, tumor or systemic thromboembolism.
  • Atrial septal defect or clinically significant patent foramen ovale.
  • Life expectancy less than one year from malignancy, primary pulmonary hypertension, renal, hepatic, or neurological condition, etc.
  • Gastrointestinal bleeding during the last 6 months.
  • Coagulopathy or uninterruptible anticoagulation therapy or unable to take antiplatelet medications.
  • Creatinine > 2.4 gm/dl (212 µmol/L) at enrollment.
  • Active systemic infection.
  • The subject is currently participating in an investigational drug or another device study that has not completed the primary endpoint or that clinically interferes with the current study endpoints.
  • Have a contraindication for an emergency thoracotomy
  • Have a hypersensitivity to a single 1.0mg dose of dexamethasone sodium phosphate or short term contact with heparin.
  • Positive pregnancy test at enrollment or planning a pregnancy in the next 12 months.
  • Patient is pacemaker dependent, where cessation of pacemaker function consistently results in syncope or ventricular asystole.
  • Incompatible previously implanted intracardiac devices.

Trial design

8 participants in 1 patient group

HeartPOD™ System with Cardiac Resynchronization Therapy
Description:
All patients will receive both a HeartPod device and a CRT-D device.
Treatment:
Device: HeartPOD™ System
Device: Cardiac Resynchronization Therapy

Trial contacts and locations

10

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems