Cardiac Resynchronization Therapy Defibrillator Based Impedance Monitoring Study

Abbott logo

Abbott

Status

Completed

Conditions

Heart Failure

Treatments

Device: Transthoracic Impedance

Study type

Interventional

Funder types

Industry

Identifiers

NCT00500838
40004384

Details and patient eligibility

About

The intent of this feasibility study is to collect and analyze intra-thoracic impedance measurements from a CRT-D device in a heart failure population.

Full description

This is a multi-center feasibility study intended to collect information on changes in intra-thoracic impedance measurements from CRT-D devices. In order to obtain an intra-thoracic impedance measurement, the device delivers a subthreshold impulse that measures the resistance between two electrodes.

At the programmed interval, measurements will be obtained between six different lead configurations.

Enrollment

75 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

Eligible patients will meet all of the following:

  1. Have an approved indication per American College of Cardiology/American Heart Association/Heart Rhythm Society guidelines for implantation of a Cardiac Resynchronization Therapy Defibrillator (CRT-D) or have a previously implanted St. Jude Medical (SJM) CRT-D system capable of enabling the diagnostic impedance monitoring feature with implant occurring within the last 14 days
  2. Have had at least one hospitalization, emergency department visit, or clinic visit within the past 12 months for treatment of decompensated heart failure requiring intravenous diuretics, intravenous inotropes, Natrecor (Nesiritide) therapy, or an increase in an oral diuretic of ≥100% over a 24 hour period
  3. Have the ability to maintain a patient diary for recording daily weights, symptoms related to heart failure, changes in diuretic therapy, and any unscheduled clinic or hospital visits
  4. Have the ability to provide informed consent for study participation and be willing and able to comply with the prescribed follow-up tests and schedule of evaluation

Exclusion criteria

Patients will be excluded if they meet any of the following:

  1. Be less than 18 years of age
  2. Have had a recent myocardial infarction, unstable angina or cardiac revascularization within 40 days of enrollment
  3. Have had a recent Cerebrovascular Accident or Transient Ischemic Attack within three months of enrollment
  4. Have a contraindication for an emergency thoracotomy
  5. Have an indication that requires programming device in atrial pacing mode
  6. Have permanent (chronic) atrial fibrillation
  7. Have a capped or inactive right atrial or right ventricular pacing/defibrillator lead
  8. Have a hypersensitivity to a single 1.0mg dose of dexamethasone sodium phosphate or short term contact with heparin
  9. Be pregnant or planning a pregnancy in the next 6-months
  10. Be currently participating in a clinical investigation that includes an active treatment arm
  11. Have a life expectancy of less than six months due to any condition

Trial design

Primary purpose

Device Feasibility

Allocation

N/A

Interventional model

Single Group Assignment

Masking

None (Open label)

75 participants in 1 patient group

1
Experimental group
Description:
Transthoracic impedance device implanted.
Treatment:
Device: Transthoracic Impedance