ClinicalTrials.Veeva

Menu

Central Haemodynamics and Pacing for AV Block (PACE-CCQ)

U

University of Tartu

Status

Enrolling

Conditions

Pacing Therapy
Atrioventricular Block
Conduction System Pacing
Right Ventricular Pacing

Treatments

Device: Conduction system pacing
Device: Right ventricular pacing

Study type

Interventional

Funder types

Other

Identifiers

NCT07276490
405/M-27

Details and patient eligibility

About

A randomized, single-blind study comparing two pacing strategies in patients with atrioventricular block requiring permanent pacemaker implantation. This trial evaluates the impact of conduction system pacing (left bundle branch area pacing) versus standard right ventricular pacing on central hemodynamics, cardiac function, and patient quality of life over 12 months. The study will enroll 124 patients from two Estonian tertiary hospitals and measure central systolic arterial pressure as the primary outcome, with secondary assessments of arterial stiffness, echocardiographic parameters, electrical activation patterns, and quality of life scores.

Enrollment

124 estimated patients

Sex

All

Ages

18 to 80 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Age 18-80 years
  • Diagnosis of atrioventricular block
  • Expected survival >1 year

Exclusion criteria

  • Reduced left ventricular ejection fraction (EF <45%)
  • Expected ventricular pacing burden <20%
  • Inter-arm systolic blood pressure difference >15 mmHg
  • Percutaneous coronary intervention or coronary artery bypass surgery within the last 30 days
  • Secondary hypertension
  • Orthostatic hypotension
  • Clinically significant valvular heart disease
  • Congenital heart disease
  • Pulse wave analysis or pulse wave velocity measurement cannot be reliably performed
  • Pregnancy or breastfeeding
  • Withdrawal of consent by the subject
  • Loss of contact during the study

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Single Blind

124 participants in 2 patient groups

Right ventricular pacing
Active Comparator group
Treatment:
Device: Right ventricular pacing
Conduction system pacing
Experimental group
Treatment:
Device: Conduction system pacing

Trial contacts and locations

1

Loading...

Central trial contact

Silver Heinsar, MD, PhD

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems