Central Line Placement-EVALUATION OF LINE DEPTH AS A FACTOR IN NEED FOR LINE REPLACEMENT SECONDARY TO MALPOSITION

University of Michigan logo

University of Michigan

Status

Withdrawn

Conditions

Vascular Access Complication

Treatments

Procedure: Shallow catheter tip placement
Procedure: Deep catheter tip placement

Study type

Interventional

Funder types

Other

Identifiers

Details and patient eligibility

About

This is a single center, randomized, controlled trial in which tunneled central line catheters will be placed in two distinct, select positions. The catheter tip position will then be followed up prospectively after placement to determine whether there is any malpositioning of the tip and if one placement is better than the other.

Full description

Optimal central line placement is vital to catheter longevity. If malpositioned, the catheter may need to get replaced, potentially causing additional morbidity to the patient and additional cost to the healthcare system. In our department, a retrospective study looking at catheter tip position at inital placement and incidence of malposition. In this study, 404 catheter placements were reviewed, and a total of 162 (40.1%) were replaced. Out of the 162 replaced, 36 (22.2%) were replaced secondary to malposition. From this study, we were also able to conclude that catheter tips placed in a deeper position, approximately one and a half vertebral bodies below the carina, were less likely to be malpositioned in the future upon radiographic review.

Current standard of care does not dictate positioning of the line in a specific loacation. In the presence of these findings, we are proposing to conduct a single center randomized control trial in which tunneled central line catheters will be placed in two distinct, select positions. After informed consent is obtained from the patient and family, they will be randomized to one of two treatment groups. The shallow group will have the tip of the catheter located approximately one vertebral body above the carina. The deep group will have the catheter tip placed 1.5 to 2.5 vertebral bodies below the carina. Central line placement will be performed under fluoroscopy in the operating room to optimize catheter placement. Chest X ray in the post operative area will be used to confirm catheter tip position. The catheter tip position will then be followed up prospectively using chest X ray films at or within three months after placement to determine whether there is any malpositioning of the tip.

Sex

All

Ages

Under 18 years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  • Children from 0-18 years of age needing a tunneled central line (port or broviac) for treatment of their disease.

Exclusion criteria

  • Wire exchanged lines
  • Non ultrasound placed lines, femoral lines, saphenous vein lines, and cut downs
  • Short gut syndrome children < 1 year of age

Trial design

Primary purpose

Supportive Care

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

0 participants in 2 patient groups

Shallow catheter tip placement
Experimental group
Description:
Patients randomized to shallow tip placement will have the tip of the catheter placed approximately one vertebral body above to even with the carina.
Treatment:
Procedure: Shallow catheter tip placement
Deep catheter tip placement
Experimental group
Description:
Patients randomized to deep tip placement will have the tip of the catheter placed 1.5 to 2.5 vertebral bodies below the carina.
Treatment:
Procedure: Deep catheter tip placement