CentriMag Ventricular Assist System in Treating Failure-to-Wean From Cardiopulmonary Bypass

Abbott logo

Abbott

Status

Completed

Conditions

Heart Failure

Treatments

Device: CentriMag Ventricular Assist System

Study type

Interventional

Funder types

Industry

Identifiers

NCT00819793
LXP-002

Details and patient eligibility

About

The purpose of the study is to evaluate the safety and effectiveness of the CentriMag ventricular assist system to help patients who have experienced heart failure during surgery and cannot be removed from cardiac bypass.

Enrollment

32 patients

Sex

All

Ages

18+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • At least 18 years of age

  • Cardiac dysfunction due to failure-to-wean from cardiopulmonary bypass

  • Subjects who are on IABP, CPB, ECMO or CPS support prior to evaluation should have the device turned off, if possible, for the purpose of measuring inclusion hemodynamics. However, these devices should not be turned off in patients who would be harmed by interruption of support.

  • All subjects must meet the following criteria at the time of enrollment:

  • Hemodynamics:

    1. cardiac index ≤ 2.2 L/min/m2
    2. For patients being evaluated for left-sided support (LVAD): PCWP ≥ 18 mmHg or PADP ≥ 18 mmHg or LAP ≥ 18 mmHg
    3. For patients being evaluated for right or biventricular support: CVP ≥ 15 mmHg or RAP ≥ 15 mmHg and RVSWI ≤ 4.1 gm/m2/beat
    4. Enrollment without hemodynamic measurements due to frequent or unpredictable dysrhythmias, unacceptable cardiac function, or hemodynamic instability is allowed.
  • Placement of an intra-aortic balloon pump has been attempted unless contraindicated

  • All possible measures have been attempted to correct low arterial pH, arterial blood gas abnormalities, electrolytes, hypovolemia, hypervolemia, inadequate cardiac rate, dysrhythmias and residual hypothermia

  • Cardiac resuscitation using pharmacologic agents, and epicardial pacing (if appropriate and possible) has been attempted

  • Written, signed, and dated informed consent

Exclusion criteria

  • BUN > 100 mg/dl
  • Creatinine > 5 mg/dl
  • Presence of any investigational mechanical circulatory support device
  • Known history of liver cirrhosis or portal hypertension
  • Pulmonary infarction
  • Stroke, TIA or history of either condition within the last six months and/or any confirmed, existing neurologic deficits
  • Active systemic infection defined as positive blood cultures, core temperature >100.5 degrees, white blood count > 12,500, and treatment with antimicrobials
  • Participation in a clinical trial with any experimental treatment within 30 days prior to screening or previous participation in the present study
  • Other serious disease(s) limiting life expectancy

Trial design

Primary purpose

Treatment

Allocation

N/A

Interventional model

Single Group Assignment

Masking

None (Open label)

32 participants in 1 patient group

CentriMag Ventricular Assist System
Experimental group
Description:
All patients meeting the patient selection criteria will be treated with the CentriMag Ventricular Assist System.
Treatment:
Device: CentriMag Ventricular Assist System

Trial contacts and locations

14

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2025 Veeva Systems