ClinicalTrials.Veeva

Menu

CGM in Patients With ED's

D

Denver Health and Hospital Authority

Status

Completed

Conditions

Avoidant Restrictive Food Intake Disorder
Anorexia Nervosa Restricting Type
ARFID
Anorexia Nervosa, Binge Eating/Purging Type

Treatments

Device: Continuous Glucose Monitor

Study type

Observational

Funder types

Other

Identifiers

NCT05603481
DenverHealth

Details and patient eligibility

About

To determine the accuracy of continuous glucose monitoring (CGM) with point of care (POC) fingerstick glucose monitoring and venous blood glucose in patients with eating disorders, specifically anorexia nervosa, restricting subtype (AN-R); avoidant/restrictive food intake disorder (ARFID); and anorexia nervosa, binge/purge subtype (AN-BP).

Full description

It is the experience of the treatment team at ACUTE Center for Eating Disorders and Severe Malnutrition that POC fingerstick testing can be inaccurate in patients when POC fingerstick testing is compared to serum glucose values. However, this has not been formally studied.

This study seeks to define the accuracy of POC fingerstick testing and CGM as compared to blood serum glucose monitoring via phlebotomy. It also seeks to better understand the frequency of hypo- and hyperglycemia in this population using continuous glucose monitoring during the first 10 days of admission. Ideally, an accurate method of monitoring glucose values in this population beside phlebotomy draws needs to be established.

Blood will be drawn shortly after participants admission to the unit as part of usual care and will continue to be drawn daily as usual care for the next 5 days. Patient blood sugar will be checked daily using POC finger sticks until hypoglycemia resolves. If patient choose to participate in this study, the investigators will do additional POC testing on days 6 and 8 POC finger sticks will be done 30-minutes post breakfast/lunch/dinner. On the same day the patient agrees to be in this study, the patient will have a Dexcom CGM placed to the back of their arm, or on another area of the body depending on the recommendation from the manufacturer (DEXCOM). Patient will wear the CGM for the full 10 days that the study is being conducted.

Patient will also be asked to complete a simple log regarding the date and time the patient received post Breakfast/lunch/dinner POC tests on days 6 and 8. The patient may ask the PSCA Patient Safety Care Attendant (PSCA) to assist patient with this task.

Data received from the Dexcom device will automatically be uploaded to the Dexcom cloud. Only the research statistician will have access to these data. Staff from Dexcom do not have access to these data.

Enrollment

50 patients

Sex

All

Ages

18 to 65 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Ages 18-65 and meet the DSM-V criteria for AN-R or AN-BP or ARFID
  • Admission %IBW ≤ 75%

Exclusion criteria

  • Diagnosed with an eating disorder other than AN-R or AN-BP or ARFID
  • %IBW > 75% on admission
  • Inability to give informed consent to participate/lacks decisional capacity
  • Unable to follow the study protocol
  • Transferred to the unit on a mental health hold/short term certification
  • Treatment team refusal of patient's participation

Trial design

50 participants in 1 patient group

CGM
Treatment:
Device: Continuous Glucose Monitor

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems