ClinicalTrials.Veeva

Menu

Characterization of Complex Pulse Shapes in Deep Brain Stimulation for Movement Disorders Using EEG and Local Field Potential Recordings (CHANNEL DBS)

C

Catholic University (KU) of Leuven

Status

Completed

Conditions

Essential Tremor
Parkinson Disease

Treatments

Device: Boston Scientific: Study tool computer

Study type

Interventional

Funder types

Other

Identifiers

Details and patient eligibility

About

Parkinson's disease and essential tremor are chronic movement disorders for which there is no cure. When medication is no longer effective, deep brain stimulation (DBS) is recommended. Standard DBS is a neuromodulation method that uses a simple monophasic pulse, delivered from an electrode to stimulate neurons in a target brain area. This monophasic pulse spreads out from the electrode creating a broad, electric field that stimulates a large neural population. This can often effectively reduce motor symptoms. However, many DBS patients experience side effects - caused by stimulation of non-target neurons - and suboptimal symptom control - caused by inadequate stimulation of the correct neural target. The ability to carefully manipulate the stimulating electric field to target specific neural subpopulations could solve these problems and improve patient outcomes. The use of complex pulse shapes, specifically biphasic pulses and asymmetric pre-pulses, can control the temporal properties of the stimulation field. Evidence suggests that temporal manipulations of the stimulation field can exploit biophysical differences in neurons to target specific subpopulations. Therefore, our aim is to evaluate the direct neurophysiological effects of complex pulse shapes in DBS movement disorder patients. This will be achieved using a two-stage investigation: stage one will study the neural response to different pulse shapes using electroencephalography (EEG) recordings. Stage two will study the neural responses to different pulse shapes using intra-operative local field potential (LFP) recordings. This study only relates only to the collection of EEG and LFP recordings in DBS patients. The protocol does not cover any surgical procedures, which already take place as part of the patient's normal clinical care.

Full description

Parkinson's disease and essential tremor are chronic movement disorders for which there is no cure. When medication is no longer effective, deep brain stimulation (DBS) is recommended. Standard DBS is a neuromodulation method that uses a simple monophasic pulse, delivered from an electrode to stimulate neurons in a target brain area. This monophasic pulse spreads out from the electrode creating a broad, electric field that stimulates a large neural population. This can often effectively reduce motor symptoms. However, many DBS patients experience side effects - caused by stimulation of non-target neurons - and suboptimal symptom control - caused by inadequate stimulation of the correct neural target. The ability to carefully manipulate the stimulating electric field to target specific neural subpopulations could solve these problems and improve patient outcomes.

It has been shown that modifying the electrical waveform (e.g. pulse duration, pulse polarity, etc.) determine the spatial selectivity in functional electrical stimulation. Also, a recent clinical study examined for the first time the acute effects of anodic compared to cathodic neurostimulation in 10 PD patients. They found that thresholds for anodic stimulation were significantly higher than thresholds for cathodic stimulation, which is in agreement with previous research in animal studies and model calculations. However, they also reported a better clinical effect of anodic compared to cathodic stimulation. Furthermore, a modeling study from Anderson et al. (2018) found that fiber orientations can be selectively targeted depending on the stimulus waveform (i.e. cathodic or anodic). Another recent study examined the effect of an active symmetric biphasic pulse in 8 PD and 3 ET patients. They found that this pulse shapes produced significant clinical improvements compared to the standard clinical pulse shape.

Besides the symmetric biphasic pulse shape, the asymmetric pre-pulse shows great potential for the refinement of DBS therapy. If the pre-pulse is anodic, it has a hyperpolarizing effect and is therefore referred to as a hyperpolarizing pre-pulse. If it is cathodic, it has a depolarizing effect near the electrode and is therefore referred to as a depolarizing pre-pulse. Clinical studies focused on the use of asymmetric pulse shapes to improve the spatial selectivity by selectively exciting fibers in cochlear implant listeners13-16. Modeling studies indicate that a hyperpolarizing pre-pulse can actually decrease the threshold for axons and that the threshold is decreased more for axons close to the electrode than axons further away. This indicates that a hyperpolarizing pre-pulse may help focus the effects of stimulation to axons near the electrode, thus leading to an increase in the therapeutic window and potentially more efficient symptom control.

Evidence suggests that temporal manipulations (i.e. the use of complex pulse shapes, specifically biphasic pulses and asymmetric pre-pulses) of the stimulation field can exploit biophysical differences in neurons to target specific subpopulations. Ultimately, this may lead to an increase in the therapeutic window and/or more efficient symptom control. In this study, we aim to understand the neural mechanism underpinning the clinical effects observed by manipulating the pulse shapes, by comparing neurophysiological responses to the standard clinical pulse shapes to the responses to the complex pulse shapes. This will be achieved using two approaches. The first approach will study neural responses to different pulse shapes using electroencephalography (EEG) recordings. The second approach will study neural responses to different pulse shapes using intra-operative local field potential (LFP) recordings. This study and research protocol relates only to the collection of EEG and LFP recordings in DBS patients. The protocol does not cover any surgical procedures, which will already take place as part of the patient's normal clinical care.

Enrollment

30 patients

Sex

All

Ages

18 to 99 years old

Volunteers

No Healthy Volunteers

Inclusion and exclusion criteria

Inclusion Criteria for PD:

  • Diagnosis of idiopathic Parkinson's disease where the diagnosis was made by a Movement Disorder Specialist according to the MDS criteria of 2015, with a Hoehn and Yahr scale (H&Y) of at least 2 (bilateral involvement).
  • Onset of the symptoms more than five years ago.
  • MDS-UPDRS-III score of ≥30 without medication or DBS.
  • Electrodes are implanted in target area STN.

Inclusion Criteria for ET:

  • Patient is diagnosed with essential tremor by a Movement Disorder Specialist.
  • Diagnosis since more than 3 years.
  • Patient has a disabling medical-refractory upper extremity tremor without medication or DBS.
  • Patient has a postural or kinetic tremor severity score of at least 3 out of 4 in the extremity intended for treatment on the Fahn-Tolosa-Marin Clinical Rating Scale for Tremor without medication or DBS.
  • Electrodes are implanted in target area VIM.

General Inclusion Criteria:

Post-op the implanted electrodes pass an integrity check, i.e. no open or shorted electrodes.

  • Stable medications
  • Lack of dementia or depression.
  • Patient is willing and able to comply with all visits and study related procedures
  • Patient understands the study requirements and the treatment procedures and provides written informed consent before any study-specific tests or procedures are performed.
  • Patient can tolerate at least 12 hours OFF medication and per clinical judgement be able to perform all study related procedures

Exclusion Criteria:

  • Any significant psychiatric problems, including unrelated clinically significant depression.
  • Any current drug or alcohol abuse.
  • Any history of recurrent or unprovoked seizures.
  • Have any significant medical condition that is likely to interfere with study procedures or likely to confound evaluation of study endpoints, including any terminal illness with survival <12 months.

Trial design

Primary purpose

Supportive Care

Allocation

Randomized

Interventional model

Crossover Assignment

Masking

Single Blind

30 participants in 2 patient groups

Standard clinical pulse shape
Active Comparator group
Description:
Standard clinical pulse shape as used in clinical practice (cathodic stimulation).
Treatment:
Device: Boston Scientific: Study tool computer
Complex pulse shape
Experimental group
Description:
Complex pulse shape (i.e. biphasic pulse shape anode first, biphasic pulse shape cathode first, hyperpolarizing pre-pulse or depolarizing pre-pulse).
Treatment:
Device: Boston Scientific: Study tool computer

Trial contacts and locations

1

Loading...

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2025 Veeva Systems