ClinicalTrials.Veeva

Menu

Checking Occlusion During Stainless Steel Crown Placement

R

Riyadh Colleges of Dentistry and Pharmacy

Status

Completed

Conditions

Dental Caries

Treatments

Other: Stainless steel crown
Other: Occlusal Template

Study type

Interventional

Funder types

Other

Identifiers

NCT02437565
FRP/2013/046

Details and patient eligibility

About

Stainless steel crowns are arguably the most successful posterior restorations in primary teeth and have been so for more than 50 years. Stainless steel crowns offer durability and success rates in excess of 95% making them the restoration of choice for posterior primary teeth in children treated under general anesthesia.

Failures of stainless steel crowns placed on primary teeth have been documented using several criteria including marginal adaptation, recurrent caries, abscess formation or root resorption, loss of the crown due to faulty retention and even perforation of the crown . Despite the probability that factors such as root resorption and failure of endodontic treatment could be due to traumatic occlusion, surprisingly little evidence is available in literature on the attempts made to check or evaluate the occlusion of stainless steel crowns placed under general anesthesia The aim of this study was to compare the time taken for placement and the overall success of bilateral multiple stainless crowns placed under general anesthesia using an occlusal index and compare them to crowns placed without such an index, using a randomized control study design

Full description

A total of 60 patients (32 male and 28 female) aged between 4 and 7 years (Mean age 4.8 years, SD +/- 1.09 years) who met the inclusion criteria were recruited after obtaining informed consent from the parent. No financial incentives were offered for participation in the study. A total of 51 (29 male and 22 female) patients completed the six month follow up requirement (Fig 2).

Evaluation Crowns and the Procedure All patients were evaluated at 24 hours, one week, three months and six months post-operatively. Clinical criteria evaluated included the reporting of pain, discomfort, difficulty in mastication or high points reported by the patient. Tenderness on percussion, presence of premature mobility and clinical evidence of an abscess or fistula were checked by one of the investigators (SCP). Periapical digital radiographs were taken using a digital sensor (Schick Elite, Sirona Dental Inc. Long Island NY. USA) and were evaluated by the same examiner for radiographic evidence of failure. In order to ensure blinding the investigator (SCP) recording the findings was not made aware of which group the patient belonged to. The time taken for each procedure was calculated from the time of placement of the throat pack to the time of removal of the throat pack and was obtained from the intra-operative anesthesiologist notes. If failure of the crown occurred at 3 months, these teeth were excluded from the 6 month evaluation.

Statistical Analyses The parametric values of the control and case groups were compared using the student's t test. The non-parametric values of the control and case groups were compared using the Mann Whitney U test. All tests were conducted at p value of 0.05

Enrollment

60 patients

Sex

All

Ages

4 to 7 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • Clinical Diagnosis of Severe Early Childhood Caries
  • Have behavioral problems that require management under general anesthesia
  • ASA class I
  • Deep Dental Caries involving the pulp in all eight primary molars

Exclusion criteria

  • ASA class II or above
  • Initial treatment plan cannot be carried out
  • Need for extraction or pulpectomy in one or more primary molar

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

Double Blind

60 participants in 2 patient groups

Control
Active Comparator group
Description:
Placement of stainless steel crown under general anesthesia without the use of an occlusal template
Treatment:
Other: Stainless steel crown
Impression
Experimental group
Description:
Placement of stainless steel crown under general anesthesia with the use of an occlusal template prepared after making an impression of the teeth using a fast setting polyvinyl siloxane material
Treatment:
Other: Stainless steel crown
Other: Occlusal Template