Clinical Applications of Round Window Imaging Anatomy in Cochlear Implant Surgery

B

Bnai Zion Medical Center

Status

Unknown

Conditions

Sensorineural Hearing Loss (Disorder)

Treatments

Other: measurment

Study type

Observational

Funder types

Other

Identifiers

NCT02093806
0140-13-BNZ (Other Grant/Funding Number)

Details and patient eligibility

About

The purpose of this study is to measure the size of the round window niche and its relation to the mastoid segment of the facial nerve and the mastoid cortex, using high resolution computerized tomography of the temporal bone, in order to assess preoperatively what is the extent of obstruction of the round window membrane and whether there is a surgical possibility of round window approach in the insertion of electrode array into the cochlea

Full description

The assessment of the anatomy of the round window will be executed using the stractured measuring software used for imaging of the Bnai Zion medical center (CARESTREAM PACS Ver. 11.0, CARSTREAM HEALTH INC.) in IAC window (centered at 700 with a total width of 4000) in the available zoom by the software (usually 400-800%).

Measuring the length (mm) and angle will be executed by the software's structured rulers.

Measuring protocol:

  1. Measured scans: one taken in an orbito-meatal plane

  2. Chosen slices: where both the round window niche and the external ear canal are seen on the same slice

  3. Distances measured:

    1. Distance 1: between the anterior edge of the round window niche and the cortex of the mastoid, with a minimal distance of 0.5mm to the posterior wall of the external ear canal
    2. Distance 2: between the posterior edge of the round window niche and the cortex of the mastoid, with a minimal distance of 0.3mm to the anterior edge of the mastoid segment of the facial nerve.
    3. Distance 3: the size of the round window niche (from its anterior to posterior edges)
    4. Distance 4: between the anterior (most medial) edge of the round window membrane to a point at least 0.3mm anterior to the mastoid segment of the facial nerve.
    5. Distance 5: between the posterior (most lateral) edge of the round window membrane to a point at least 0.3mm anterior to the mastoid segment of the facial nerve
    6. Distance 6: size of round window membrane (anterior/medial to posterior/lateral)
    7. Distance 7: between the lateral edges of distance 1 and 2 marking the cortical size of the "working channel" created between the lines (from the cortex to the round window).
  4. Angles measured:

    1. Between distance 1 and 7 - marking the angle of the "working channel" relatively to the cortex
    2. Between distance 1, passing in the middle of distance 3 to the middle of distance 6 - marking the angle of possible insertion from the working channel into the cochlea

Enrollment

100 patients

Sex

All

Ages

20+ years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • age 20 years old or older
  • high resolution computerized tomography of the temporal bone (slices ≤1mm) before the surgery
  • on the measured slices both the round window niche and the posterior wall of the external ear canal are seen

Exclusion criteria

  • inner, middle or external ear malformation
  • temporal bone malformation
  • status post cochlear implant
  • status post temporal bone trauma
  • slices were the round window niche and the posterior wall of the external ear canal are not seen on the same slice

Trial design

100 participants in 1 patient group

CT of the temporal bone
Treatment:
Other: measurment

Trial contacts and locations