ClinicalTrials.Veeva

Menu

Clinical Results and RSA Migration Analysis of the GLOBAL ICON - Stemless Anatomic Shoulder

H

Hannover Medical School (MHH)

Status

Enrolling

Conditions

Osteoarthritis of the Shoulder

Treatments

Device: Total joint arthroplasty of the glenohumeral joint

Study type

Interventional

Funder types

Other

Identifiers

NCT04468178
IIT-RSA-Global-Icon-2020

Details and patient eligibility

About

The primary goal of the clinical trial is to determine that the GLOBAL ICON implant system from DePuy does not exhibit worse shoulder function after 2 years than the SIMPLICITY from Wright Medical. The primary endpoint is the Constant-Murley Shoulder Score (CMSS) of the implant after 2 years, the non-inferiority of which is to be demonstrated in comparison with an already established prosthetic system (SIMPLICITY, Wright Medical).

Full description

The primary goal of the clinical trial is to determine that the GLOBAL ICON implant system from DePuy does not exhibit worse shoulder function after 2 years than the SIMPLICITY from Wright Medical. The primary endpoint is the Constant-Murley Shoulder Score (CMSS) of the implant after 2 years, the non-inferiority of which is to be demonstrated in comparison with an already established prosthetic system (SIMPLICITY, Wright Medical).

As secondary endpoints, the migration behavior of the humeral components over time will be determined by radiostereometric analysis (RSA), the further clinical-functional results and the satisfaction of the patients treated will be investigated. Clinical outcomes are measured using standardized and reproducible clinical scores (Oxford Shoulder Score -OSS and Short Form Health 36-SF-36 v1.0 ) at each time of examination.

Other endpoints include revision rate within the follow-up period, surgical time (incision to suture), and delays in surgical procedures due to instrumentation.

The times of data acquisition are the admission day before the operation to determine the preoperative status, the discharge day and the follow-up appointments after 3 months, 6 months, 12 months and 24 months to determine the postoperative status and course.

Enrollment

60 estimated patients

Sex

All

Ages

18 to 80 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  1. Trial participants need primary total shoulder replacement due to primary osteoarthritis or post-traumatic osteoarthritis
  2. Trial participants are willing to take part in the clinical trial and intend to be available for the planned follow-up examinations.
  3. Male, female and various subjects with age on the day of surgery from 18 to 80 years inclusive.
  4. Subjects agree not to participate in any other clinical trial for at least 2 years (+ 3 weeks) using the index procedure. This includes clinical trials of medication, invasive procedures and medical devices. Questionnaire-based studies or other studies that are non-invasive and do not involve drug use are allowed.
  5. Exclusion of intraoperative circumstances that require the implantation of a prosthesis type other than that provided for in the clinical trial (depending on the surgeon).

Exclusion criteria

  1. Previous operation on the rotator cuff of the affected shoulder
  2. Dysfunctional rotator cuff
  3. Infection of the affected shoulder joint or systemic infection
  4. Pregnant or breastfeeding women and those who are planning to become pregnant for up to 2 years (+3 weeks) using the index procedure

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

60 participants in 2 patient groups

Shoulder prosthesis system GLOBAL ICON from DePuy
Experimental group
Description:
The GLOBAL ICON stemless is a shaftless shoulder prosthesis system for anatomical reconstruction of the shoulder joint in cases of total or hemiarthroplasty in the shoulder. The base plate consists of titanium coated with hydroxyapatite, the head of cobalt-chrome.
Treatment:
Device: Total joint arthroplasty of the glenohumeral joint
SIMPLICITY shoulder prosthesis system from Wright Medical
Active Comparator group
Description:
The SIMPLICITY is a shaftless shoulder prosthesis system for anatomical reconstruction of the shoulder joint in cases of total or hemiarthroplasty in the shoulder. The base plate consists of titanium coated with hydroxyapatite, the head of cobalt-chrome.
Treatment:
Device: Total joint arthroplasty of the glenohumeral joint

Trial contacts and locations

1

Loading...

Central trial contact

Tomas Smith, PD Dr.

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2025 Veeva Systems