ClinicalTrials.Veeva

Menu

Clinical Trial of New Hypothermic Oxygenated Perfusion System Versus Static Cold Storage

U

University of Bologna

Status

Unknown

Conditions

Kidney Diseases
Liver Diseases

Treatments

Device: Liver-Hypothermic oxygenated
Device: Kidney-Hypothermic oxygenated

Study type

Interventional

Funder types

Other

Identifiers

NCT03837197
RF-2016-02364732

Details and patient eligibility

About

With the present study the investigators will evaluate the benefit of end-ischemic HOPE on ECD grafts (livers and kidneys) as compared to SCS. Organs will be perfused through a recently developed machine perfusion (MP) device, from the beginning of back-table procedures till implantation, without increasing CIT. The aim of the study will be demonstrating the ability of HOPE to improve graft function and post-operative outcomes of ECD kidney and liver recipients.

Full description

Extended criteria donors (ECD) are widely utilized due to organ shortage, but this may increase the risk of graft dysfunction and of poorer outcomes.

Hypothermic oxygenated perfusion (HOPE) is a recent organ preservation strategy for marginal kidney and liver grafts, which allows to redirect anaerobic metabolism to aerobic metabolism under hypothermic conditions and to protect grafts from oxidative species-related damage; these mechanisms may potentially improve graft function and survival.

Methods This is an open-label, randomized multicenter clinical trial with the aim of comparing HOPE vs. static cold storage (SCS) in ECD kidney and liver transplantation.

In the study protocol - approved by ethics committee - 220 patients (110 liver recipients and 110 kidney recipients) will be enrolled. Livers and kidneys assigned to HOPE will be perfused by machine perfusion with cold Belzer solution (4°-10°C) and with continuous oxygenation (partial pressure of oxygen = 500-600 mmHg). In the control group, livers and kidneys undergoing SCS will be steeped in Celsior or University of Wisconsin Belzer solutions and stored in ice. Using the same perfusion machine for both liver and kidney grafts, organs will be perfused from the start of the back-table procedure until implantation, without increasing cold ischemia time (CIT). For each group the investigators will evaluate clinical outcomes, graft function tests and histologic findings, as well as perfusate and the number of allocated organs.

Enrollment

220 estimated patients

Sex

All

Ages

18 to 100 years old

Volunteers

No Healthy Volunteers

Inclusion criteria

  • For kidneys: donor age ≥ 60 years or 50-59 years with two or more of the sequent risk factors: death due to cerebrovascular accident, history of hypertension, donor serum creatinine > 1.5 mg/dL, cold ischemia time (CIT) > 20 h;
  • For livers: donors with hemodynamic deterioration, donor age > 65 years, donor body mass index > 30 kg/m2, serum bilirubin > 3 mg/dl, AST or ALT above three times the upper reference threshold, sodium > 165 mmol/l, intensive care unit (ICU) stay > 7 days, steatosis > 40%, CIT > 12 h.

Exclusion criteria

  • Donor age ≤18 years;
  • Donors after circulatory death (DCD) will be excluded, because Italian law requires 20 minutes of "no touch period" before death declaration, causing prolonged warm ischemia and subsequent mandatory perfusion of the organ.
  • Split-liver recipients, liver transplantation (LT) for acute liver failure, pre-emptive renal transplant, dual kidney transplantation, and patients with intra-operative surgical complications before the organ implantation.

Trial design

Primary purpose

Treatment

Allocation

Randomized

Interventional model

Parallel Assignment

Masking

None (Open label)

220 participants in 4 patient groups

Kidney-Hypothermic oxygenated
Experimental group
Description:
Belzer machine perfusion solution at 4°C-10°C in sterile conditions and continuous oxygenation (partial pressure of oxygen=500-600 mmHg) will be used for perfusion 2000 ml for kidneys.
Treatment:
Device: Kidney-Hypothermic oxygenated
Kidney-Static Cold Storage
No Intervention group
Description:
Kidneys undergoing SCS will be stored in sterile organ bags with Celsior or University of Wisconsin solution and cooled in ice.
Liver-Hypothermic oxygenated
Experimental group
Description:
Belzer machine perfusion solution at 4°C-10°C in sterile conditions and continuous oxygenation (partial pressure of oxygen=500-600 mmHg) will be used for perfusion 3000 ml for livers.
Treatment:
Device: Liver-Hypothermic oxygenated
Liver-Static Cold Storage
No Intervention group
Description:
Livers undergoing SCS will be stored in sterile organ bags with Celsior or University of Wisconsin solution and cooled in ice.

Trial contacts and locations

1

Loading...

Central trial contact

Matteo Ravaioli, PhD

Data sourced from clinicaltrials.gov

Clinical trials

Find clinical trialsTrials by location
© Copyright 2026 Veeva Systems