Clinical Trial of Transtek Body Fat Analyzer (GBF-835-N2 & Other 7 Models) (15001Analy)

L

Leo Wang

Status

Completed

Conditions

Body Fat Disorder
Weight

Treatments

Device: Transtek DUT
Device: Reference

Study type

Interventional

Funder types

Other

Identifiers

NCT02345109
15001_Analyzer
BTS15001 (Other Identifier)

Details and patient eligibility

About

The clinical protocol of the clinical testing of this device:

  1. Objective of the test: To verify the functions and efficiency of devices.
  2. Test methods and procedures: Comparison Test.
  3. Device Under Test (DUT): Transtek Body Fat Analyzer, Model: GBF-835-N2, GBF-835-N2 Plus, LS202-B1, LS202-B1 Plus, LS206-E1, LS206-E1 Plus, GBF-1251-B1, and GBF-1251-B1 Plus.
  4. Comparison device: TRANSTEK GBF-1251-B and Tanita BC-533.
  5. Study endpoints: DUT and the comparison device are substantial equivalence.
  6. Statistical methodology used: Description of statistical methods.

Full description

  1. Test Purpose:

    The aim of clinical test is to collect BMI, body fat, total body water, muscle mass, bone mass, calorie, and visceral fat reading value which measured by DUT and reference device.

  2. Target Subject:

    The subject database shall contain at least 30 male and 30 female subjects and all above 10 years old.

  3. Test procedures:

    1. Record the name, age, gender, and height of each subject.
    2. Let subject seated calmly for two minutes before test, dry the feet.
    3. Use device to measure weight, body fat, total body water, bone mass, and muscle mass; record reading value.
    4. For each subject, repeat 3) to get 3 pairs measurements.
    5. Repeat step 1) to 4) for every device (DUT: GBF-835-N2, GBF-835-N2 Plus, LS202-B1, LS202-B1 Plus, LS206-E1, LS206-E1 Plus, GBF-1251-B1, and GBF-1251-B1 Plus; and reference device: GBF-1251-B and BC-533).
    6. Repeat step 1) to 5) for each subject.
  4. Note:

    1. No motion and speaking are allowed during the measurement.
    2. All DUT use the same algorithms and contact the patient at the same body locations (feet), and operate on the same frequency.
    3. Test environment: Temperature: 22±1℃; Relative humidity: 40~70%.

Enrollment

60 patients

Sex

All

Ages

10+ years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  • Male, female

Exclusion criteria

  • Below 10 years old

Trial design

60 participants in 2 patient groups

Transtek DUT
Experimental group
Description:
Which measured by DUT: GBF-835-N2, GBF-835-N2 Plus, LS202-B1, Ls202-B1 Plus, LS206-E1, LS206-E1 Plus, GBF-1251-B1, and GBF-1251-B1 Plus.
Treatment:
Device: Reference
Device: Transtek DUT
Reference
Experimental group
Description:
Measured by Reference: TRANSTEK® Glass Body Fat Analyzer GBF-1251-B, Tanita® Body Composition Monitor BC-533.
Treatment:
Device: Reference
Device: Transtek DUT