About

Low level intervention health products clinical trial, fourth phase, non-commercial research. Dissertation of COMPLUTENSE UNIVERSITY of Madrid.

Principal Investigator of this clinical trial: Ms. LETICIA CARMEN SIMÓN LÓPEZ Collaborative investigators: Dr. DOLORES OCHOA-MAZARRO (principal investigator of bioequivalence clinical trial), and Sir. SERGIO LUQUERO-BUENO (collaborative researcher)

The setting is Clinical trials Unit of Clinical Pharmacology Department. LA PRINCESA HOSPITAL of Madrid. Research Ethical Committee of LA PRINCESA HOSPITAL of Madrid. Any person will monitor this clinical trial because the sponsor and principal researcher are the same person. Nevertheless, an adherence to this protocol will ensure by principal researcher and co-researchers.

The three interventions are:

  1. To Apply local dry heat.
  2. To apply high tourniquet pressure.
  3. To apply both of them. (Dry heat and high pressure) The common comparator: Current Clinical practice for peripheral venous catheterization.

The main hypothesis: The number of attempts of success venipuncture at first time are influenced by any of the interventions applied before.

The main goal: To identify the most effective intervention of applying dry local heat and/or high tourniquet pressure in relation of number success venipuncture attempts, compared to current clinical practice.

Design: An experimental, randomized study which is controlled with current clinical practice to insert a peripheral vein catheter. It is an incomplete cross-over clinical trial, with three arms which are involved interventions and a common comparator.

Population: Adult healthy subjects. Sample size: It is required to enroll 54 subjects with a 95% of level of confidence and 80% level of power.

Main variable: Succeed peripheral vein catheter insertion at first attempt.

Effectiveness assessment: The optimal effectiveness is considered when vein cannulation success at first attempt exceeds 95% applying any of the interventions.

Planned date to address: It is planned to carry out around June and/or July of 2017 for the main variable.

Full description

The study is considered a low level intervention clinical trial to evaluate the use and safety of a sanitary product marketed and accredited for a different aim, but according to their rules of using.

It is experimental, randomized and controlled study with the usual technique of inserting a venipuncture catheter until now. Incomplete clinical trial, blind to third parties, in healthy volunteers, which consists of three arms, in which they are intervened and the comparator is applied. The volunteers comes from a bioequivalence clinical trial for testing a new drug, and a venous catheter is required in two period between a wash-out period of one week, approximately.

For each volunteer one of intervention is applied in one period, and in other period the comparator is applied. Thus, one intervention and the sequence of one intervention application and comparator is assigned by randomization using sealed envelopes. Randomization is only performed in first period, in second period one intervention or comparator assigned in applied. Thus, each one volunteer is her/his own comparator

. Before assigned intervention or comparator is applied, a Venous International Assessment is carried out using Venous International Assessment (VIA) validated scale by nurse perception and palpation. After assigned intervention, another VIA is performed. Then, when peripheral venous catheterization is achieved, a blood sample is withdrawn in order to examine hemolysis. Afterwards, pain is registered by Visual Analogue Scale (VAS) validated scale within no more than two hours from vein catheterization, and skin perception is evaluated by Fitzpatrick's scale (only in first period) in order to analyze a possible relationship with adverse events on skin. Subjects are followed-up for 72h in order to monitor adverse events if applicable.

According to hemolysis, an ethylene diamine tetra acetate (EDTA) blood sample is processing at 3400 revolutions per minute at 4 Celsius grades for 10 minutes, and plasma samples are frosted for 24-48h. Afterwards, they are defrosted, and analyzed by absorbance using NANODROP SPECTROPHOTOMETER. The analysis by spectrophotometer is blinded of intervention or comparator used to withdrawn.

Enrollment

62 patients

Sex

All

Ages

18 to 55 years old

Volunteers

Accepts Healthy Volunteers

Inclusion criteria

  • Signed the informed consent form for bioequivalence study
  • Signed the informed consent form for this clinical trial
  • Fluid intake of participants was limited to a volume equal to or less than 500 ml
  • Participants fasted 6-8 hours before venous cannulation
  • Body mass index (BMI) between 18.5-29.9
  • Vein perception by Venous International Assessment (VIA) scale between 5 to 2 grade.

Exclusion criteria

  • Grade one in VIA scale
  • Smokers
  • BMI lower than 18.5 or equivalent or higher than 30
  • Subjects who had any disease,
  • Blood test, urinalysis, physical examination or electrocardiogram showing disorders with clinical relevance
  • Subjects receiving treatment for anything apart from contraceptives.
  • Gluten, lactose intolerance, vegetarian or vegan subjects for bioequivalence subjects.

Trial design

Primary purpose

Supportive Care

Allocation

Randomized

Interventional model

Crossover Assignment

Masking

Single Blind

62 participants in 3 patient groups

Current clinical practice-Dry heat
Active Comparator group
Description:
The standardized and approved Clinical and Laboratory Standards Institute (CLSI) GP41-A6 venipuncture guide has been established for clinical current practice so far. According to vein cannulation procedure CLSI GP41-A6, an elastic compressor will be applied (Synthetic rubber-latex compressor tape, UNIDIX®, Madrid, Spain) provided by the hospital. 1 period (current clinical practice) and 2 period (dry heat) or 1 period (dry heat) and 2 period (current clinical practice).
Treatment:
Device: Dry heat
Current clinical practice- Hihg pressure
Active Comparator group
Description:
The standardized and approved CLSI GP41-A6 venipuncture guide has been established for clinical current practice so far. According to vein cannulation procedure CLSI GP41-A6, an elastic compressor will be applied (Synthetic rubber-latex compressor tape, UNIDIX®, Madrid, Spain) provided by the hospital. 1 period (current clinical practice) and 2 period (high pressure) or 1 period (high pressure) and 2 period (current clinical practice).
Treatment:
Device: High pressure
Current clinical practice-Combination
Active Comparator group
Description:
The standardized and approved CLSI GP41-A6 venipuncture guide has been established for clinical current practice so far. According to vein cannulation procedure CLSI GP41-A6, an elastic compressor will be applied (Synthetic rubber-latex compressor tape, UNIDIX®, Madrid, Spain) provided by the hospital. 1 period (current clinical practice) and 2 period (combination of dry heat and high pressure) or 1 period (combination of dry heat and high pressure) and 2 period (current clinical practice).